Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0123-00302
Permit Details
Apply Date:
09/28/2023
Applicant:
Garland Shaw
Description:
SFR PANT2022 T22-M0073
Permit Reviews
Permit Number - TC-MDP-0123-00302
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/28/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/03/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00302
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
03/15/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
03/15/2024 | Post-Tension Inspection Report is required. |
06/15/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0123-00302
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Date | Description | Comments |
---|---|---|
06/15/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
10/02/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0123-00302
Permite Description: SFR PANT2022 T22-M0073
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/26/2023 | COT - RSPL - Sewer | N/A | Canceled | Canceled per wet soils. 12/26/2023 |
12/26/2023 | COT - RSPL - Backwater Valve | N/A | Canceled | Canceled per wet soils. 12/26/2023 |
08/27/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
08/27/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0123-00302
Permit Description: SFR PANT2022 T22-M0073
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2023 | COT - RSPL - Rough Soil | Passed | ||
11/27/2023 | COT - RSPL - Yard Water Line | Passed | ||
11/29/2023 | COT - RSEL - Grounding/Bonding | Passed | Ufer ground is in place okay to pour concrete footings and slab. | |
11/29/2023 | COT - RSBU - Preslab | Passed | Rebar reinforcement is in place, post tension cabling is installed and inspected by a third party inspector, all plumbing pipes are properly wrapped for protection from concrete. Okay to pour concrete footings and slab on grade. | |
11/29/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Rebar reinforcement is in place, post tension cabling is installed and inspected by a third party inspector, all plumbing pipes are properly wrapped for protection from concrete. Okay to pour concrete footings and slab on grade. | |
12/28/2023 | COT - RSPL - Sewer | Passed | ||
12/28/2023 | COT - RSPL - Backwater Valve | Passed | ||
01/12/2024 | COT - RSBU - Roof Nailing | Passed | Shear wall clips are properly nailed off, H2.5 clips are installed on all trusses and connected to top plate of walls, all exterior walls are properly secured to floor, all exterior shear wall sheathing is properly nailed. Roof sheathing is properly nailed to trusses. Okay to proceed with drying in exterior walls and roof. | |
01/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Shear wall clips are properly nailed off, H2.5 clips are installed on all trusses and connected to top plate of walls, all exterior walls are properly secured to floor, all exterior shear wall sheathing is properly nailed. Okay to proceed with drying in exterior walls and roof. | |
01/31/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
01/31/2024 | COT - RSEL - Electrical Underground | Passed | ||
03/08/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. All penetration are foamed and piping/wire protection is in place were needed. Okay to proceed with installation of insulation and drywall. | |
03/27/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
09/09/2024 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting is fully operational and installed per plans and city regulations. |