Permit: TC-MDP-0123-00222
Permit Details
Apply Date:
09/18/2023
Applicant:
Russ Salmon
Description:
SFR LENNLE4003 T22-M0047
Permit Reviews
Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/18/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/20/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
07/14/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
09/18/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
09/18/2023 | Post-Installed Anchor Inspection Report is required. |
09/18/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
09/20/2023 | Post-Tension Inspection Report is required. |
09/20/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Date | Description | Comments |
---|---|---|
09/20/2023 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
07/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00222
Permite Description: SFR LENNLE4003 T22-M0047
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2023 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Thermoply shear wall missing staples top plate, loose anchor bolts. Tighten/torque anchor bolts to spec. throughout, patch concrete footing for back porch column, add shot pins to properly secure kitchen island, add nails to bottom of shear wall 8, missing 2-2x10 with LUS26-2 hangers on each end at stairs along with 2-2x4 studs, missing king studs at each end of back porch entrance, add anchor bolts to shear walls marked in red on sole plate. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00222
Permit Description: SFR LENNLE4003 T22-M0047
Total Completed Inspections - 22