Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
09/18/2023
Applicant:
Russ Salmon
Description:
SFR LENNLE4003 T22-M0047

Permit Reviews

Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Start Date Submittal Complete Date Status  
09/18/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 09/20/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Total Outstanding Activity Conditions - 6
Date Name
07/14/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
09/18/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/18/2023 Post-Installed Anchor Inspection Report is required.
09/18/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
09/20/2023 Post-Tension Inspection Report is required.
09/20/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0123-00222
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Date Description Comments
09/20/2023 The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account.
07/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00222
Permite Description: SFR LENNLE4003 T22-M0047
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/20/2023 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Thermoply shear wall missing staples top plate, loose anchor bolts. Tighten/torque anchor bolts to spec. throughout, patch concrete footing for back porch column, add shot pins to properly secure kitchen island, add nails to bottom of shear wall 8, missing 2-2x10 with LUS26-2 hangers on each end at stairs along with 2-2x4 studs, missing king studs at each end of back porch entrance, add anchor bolts to shear walls marked in red on sole plate.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00222
Permit Description: SFR LENNLE4003 T22-M0047
Total Completed Inspections - 22

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LE II HOMESITE 23 APP_V1.PDF DOCUMENTS VIEW
LE II HOMESITE 23 OK TO PERMIT_V1.PDF DOCUMENTS VIEW
LE II HOMESITE 23 SIC-2023-09-18_V1.PDF DOCUMENTS VIEW