Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/05/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|
| 12/20/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Thermoply shear wall missing staples top plate, loose anchor bolts. Tighten/torque anchor bolts to spec. throughout, patch concrete footing for back porch column, add shot pins to properly secure kitchen island, add nails to bottom of shear wall 8, missing 2-2x10 with LUS26-2 hangers on each end at stairs along with 2-2x4 studs, missing king studs at each end of back porch entrance, add anchor bolts to shear walls marked in red on sole plate. |