Permit: TC-FBB-0524-00109
Permit Details
Status:
Inspections Complete
Type:
Factory Built Buildings
Address:
1211 E GINTER RD
Address NEW:
1211 E GINTER RD
Apply Date:
05/22/2024
Applicant:
Carol Estrada
Description:
Replace mobile home
Permit Reviews
Permit Number - TC-FBB-0524-00109
Permit Status: Inspections complete
Permit Description: Replace mobile home
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/23/2024 | MANUFACTURED/MOBILE/PARK MODEL HOME v.1 | 06/05/2024 | APPROVED |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-FBB-0524-00109
Permit Description: Replace mobile home
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2024 | BULD - Electrical Clearance | Passed | 8/16/24: Equipment grounding conductor shall be identified by a continuous green color or continuous green color with one or more yellow stripes on insulation (E3407.2), raceway exposed to physical damage must be in schedule 80 PVC (E3803.3), Feeders that have damaged insulation have to be either repaired or replaced, properly secure ground to utility pole. 8/20/24: INCR TEP CLEARANCE AT 1211 E GINTER RD |
|
| 08/20/2024 | RSBU - Building Final | Passed | 8/16/24: Equipment grounding conductor shall be identified by a continuous green color or continuous green color with one or more yellow stripes on insulation (E3407.2), raceway exposed to physical damage must be in schedule 80 PVC (E3803.3), Feeders that have damaged insulation have to be either repaired or replaced, properly secure ground to utility pole. 8/20/24: INCR TEP CLEARANCE AT 1211 E GINTER RD |