Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
1131 N 6TH AV BLDG 2
Apply Date:
10/26/2023
Applicant:
Description:
THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION OF A NEW BUILDING (BUILDING 2) FOR EDUCATIONAL USE. THE NEW BUILDING (BUILDING 2) WILL BE WOOD STUD AND STUCCO. EXTERIOR SITE WORK WILL INCLUDE THE ADDITION OF A RAMP AND STAIR, PARKING, SITE WALLS AND SIDEWALK .

Permit Reviews

Permit Number - TC-COM-1023-02523
Permit Status: Complete
Permit Description: THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION OF A NEW BUILDING (BUILDING 2) FOR EDUCATIONAL USE. THE NEW BUILDING (BUILDING 2) WILL BE WOOD STUD AND STUCCO. EXTERIOR SITE WORK WILL INCLUDE THE ADDITION OF A RAMP AND STAIR, PARKING, SITE WALLS AND SIDEWALK .
Start Date Submittal Complete Date Status  
04/10/2024 COMMERCIAL REVIEW - FULL v.1 05/10/2024 APPROVED Review Details
12/18/2023 COMMERCIAL REVIEW - FULL v.2 01/12/2024 REQUIRES RESUBMIT Review Details
07/25/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/02/2024 APPROVED Review Details
08/12/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/14/2024 APPROVED Review Details
01/17/2024 COMMERCIAL REVIEW - FULL v.3 01/19/2024 APPROVED Review Details
08/20/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/03/2024 APPROVED Review Details
10/26/2023 COMMERCIAL REVIEW - FULL v.1 11/22/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-1023-02523
Permit Status: Complete
Permit Description: THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION OF A NEW BUILDING (BUILDING 2) FOR EDUCATIONAL USE. THE NEW BUILDING (BUILDING 2) WILL BE WOOD STUD AND STUCCO. EXTERIOR SITE WORK WILL INCLUDE THE ADDITION OF A RAMP AND STAIR, PARKING, SITE WALLS AND SIDEWALK .
Date Description Comments
10/26/2023 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
01/19/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/14/2024 Prior to Issuance: This project requires issuance of a Development Package (DP) permit prior to issuance of this permit. Prior to TCO/Final: This project requires full completion of a Development Package (DP) permit prior to Temporary C of O and/or final completion this permit.
01/19/2024 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
10/26/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/02/2024 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
01/19/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-1023-02523
Permite Description: THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION OF A NEW BUILDING (BUILDING 2) FOR EDUCATIONAL USE. THE NEW BUILDING (BUILDING 2) WILL BE WOOD STUD AND STUCCO. EXTERIOR SITE WORK WILL INCLUDE THE ADDITION OF A RAMP AND STAIR, PARKING, SITE WALLS AND SIDEWALK .
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
04/03/2024 COT - HCBU - Preslab N/A Not Ready
03/27/2024 COT - HCPL - Plumbing Intermediate N/A Not Ready
07/17/2024 BULD - Electrical Clearance N/A Not Ready
07/23/2024 COT - BULD - SWG Clearance N/A Not Applicable Client will no longer require gas service. Gas lines to be abandoned.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-1023-02523
Permit Description: THE WORK OF THIS PROJECT INCLUDES CONSTRUCTION OF A NEW BUILDING (BUILDING 2) FOR EDUCATIONAL USE. THE NEW BUILDING (BUILDING 2) WILL BE WOOD STUD AND STUCCO. EXTERIOR SITE WORK WILL INCLUDE THE ADDITION OF A RAMP AND STAIR, PARKING, SITE WALLS AND SIDEWALK .
Total Completed Inspections - 23
Date Description Inspector Results Comments
03/27/2024 COT - HCPL - Yard Water Line Passed
04/19/2024 COT - HCPL - Sewer Passed Sewer line (4”), plumbing underground in slab: Ok to cover progress areas.
05/08/2024 COT - HCBU - Preslab Passed Ok to place concrete; ensure area is properly termite treated.
05/08/2024 COT - HCBU - Excavation/Rebar/Zoning Passed Ok to place concrete in progress areas.
05/31/2024 COT - HCBU - Framing Passed Ok to complete intermediates.
06/13/2024 COT - HCBU - Exterior Clips/Sheathing Passed
06/18/2024 COT - HCEL - Electrical Above Ceiling Passed not ready, passed by mistake
06/20/2024 COT - HCPL - Plumbing Intermediate Passed Ok to insulate and cover walls.
06/20/2024 COT - HCBU - Stem Wall/Retaining Wall Passed
06/20/2024 COT - HCPL - Plumbing Above Ceiling Passed
06/20/2024 COT - HCEL - Electrical Intermediate Passed OK to insulate and cover walls.
06/21/2024 COT - HCME - Mechanical Above Ceiling Passed
07/18/2024 BULD - Electrical Clearance Passed
08/01/2024 COT - HCBU - Building Above Ceiling Passed
08/01/2024 COT - HCME - Mechanical Intermediate Passed
08/01/2024 TRSP - ROW - Notice of Completion Passed
08/09/2024 COT - HCEL - Electrical Final Passed
08/09/2024 COT - HCME - Mechanical Final Passed
08/09/2024 COT - HCPL - Plumbing Final Passed
08/12/2024 COT - FCON - Alarm - Final Passed
08/12/2024 COT - FCON - Fire - Final Passed
08/13/2024 COT - HCBU - Building Final Passed Ok to make application for a Certificate of Occupancy
08/20/2024 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
MONTESSORI 'I' JOIST SUBMITTAL, 2-19-24_V1_V1.PDF DOCUMENTS VIEW
COFO_TEMPORARYCOFO.PDF DOCUMENTS VIEW
COFO_TEMPORARYCOFO.PDF DOCUMENTS VIEW
MONTESSORI CHLORINATION REPORT 8.6.24-2024-08-09_V1.PDF DOCUMENTS VIEW
24-018M MONTESSORI SPL. IN. FINAL-2024-07-25_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW