Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-1023-02477
Permit Details
Apply Date:
10/19/2023
Applicant:
Miguel Hinojosa
Description:
Interior tenant improvement to a smoke shop. Refer to violation number CE-VIO0923-05852 for additional information. All work to existing roof | mansard | signage is excluded. If required, that work is by others under separate permit.
Permit Reviews
Permit Number - TC-COM-1023-02477
Permit Status: Complete
Permit Description: Interior tenant improvement to a smoke shop. Refer to violation number CE-VIO0923-05852 for additional information. All work to existing roof | mansard | signage is excluded. If required, that work is by others under separate permit.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/23/2023 | COMMERCIAL REVIEW - FULL v.1 | 11/13/2023 | APPROVED |
03/27/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/01/2024 | APPROVED |
04/19/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 04/23/2024 | APPROVED |
11/13/2023 | RESTAMP - COMMERCIAL v.1 | 11/14/2023 | APPROVED |
04/04/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/08/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-1023-02477
Permit Status: Complete
Permit Description: Interior tenant improvement to a smoke shop. Refer to violation number CE-VIO0923-05852 for additional information. All work to existing roof | mansard | signage is excluded. If required, that work is by others under separate permit.
Date | Description | Comments |
---|---|---|
11/09/2023 | AIR BALANCING REPORT IS REQUIRED. | |
11/27/2023 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
11/09/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
11/09/2023 | Post-Installed Anchor Inspection Report is required. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-1023-02477
Permite Description: Interior tenant improvement to a smoke shop. Refer to violation number CE-VIO0923-05852 for additional information. All work to existing roof | mansard | signage is excluded. If required, that work is by others under separate permit.
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2023 | BULD - Electrical Clearance | N/A | Re-inspection required | Not ready. Missing grounding electrode conductor. Add water and gas bond. 12/8/2023 |
12/19/2023 | COT - LCBU - Masonry Pregrout | N/A | Not Ready | Not ready infill block wall was filled with concrete. Not per plan. Revise plans on the details of this infill. 12/19/2023 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-1023-02477
Permit Description: Interior tenant improvement to a smoke shop. Refer to violation number CE-VIO0923-05852 for additional information. All work to existing roof | mansard | signage is excluded. If required, that work is by others under separate permit.
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2023 | COT - LCBU - Excavation/Rebar/Zoning | Passed | ||
12/19/2023 | BULD - Electrical Clearance | Passed | Clearance for TEP RECN. 12/19/2023 | |
12/19/2023 | COT - LCBU - Framing | Passed | Inspection for GLB and two wood column post per plan. 12/19/2023 | |
12/19/2023 | COT - LCBU - Preslab | Passed | ||
01/23/2024 | COT - LCBU - Building Above Ceiling | Passed | ||
01/23/2024 | COT - LCEL - Electrical Intermediate | Passed | ||
01/23/2024 | COT - LCEL - Electrical Above Ceiling | Passed | ||
02/07/2024 | COT - LCBU - Masonry Pregrout | Passed | Approved per engineer approval on the infill. 2/7/2024 | |
02/08/2024 | ENGR Engineering Final | Passed | ||
02/07/2024 | TRSP - ROW - Final/Close-Out | Passed | ||
02/14/2024 | COT - FCON - Fire - Final | Passed | ||
02/14/2024 | COT - LCEL - Electrical Final | Passed | ||
02/14/2024 | COT - LCBU - Building Final | Passed | ||
02/14/2024 | COT - LCME - Mechanical Final | Passed |