Permit Details

Status:
Inspections
Type:
Commercial Building
Apply Date:
08/14/2024
Applicant:
Andrew Venne
Description:
Interior Remodel

Permit Reviews

Permit Number - TC-COM-0824-01585
Permit Status: Inspections
Permit Description: Interior Remodel
Start Date Submittal Complete Date Status  
11/05/2024 COMMERCIAL REVIEW - FULL v.3 11/08/2024 APPROVED Review Details
10/15/2024 COMMERCIAL REVIEW - FULL v.2 10/23/2024 REQUIRES RESUBMIT Review Details
11/08/2024 RESTAMP - COMMERCIAL v.1 11/21/2024 APPROVED Review Details
08/14/2024 COMMERCIAL REVIEW - FULL v.1 09/16/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-0824-01585
Permit Status: Inspections
Permit Description: Interior Remodel
Date Description Comments
08/14/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0824-01585
Permite Description: Interior Remodel
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
01/31/2025 COT - FCON - Fire - Final N/A Partial Pass Fire final approved pending POA permit
12/24/2024 COT - HCBU - Building Progress N/A Re-inspection required 12-24-24, contractor requested that I inspect interior partition located just inside main entrance. Partition had already been covered so I couldn't verify shot pins at 32" o/c but I noted that partition was not installed per approved plans. Missing 5/8" type x drywall on both sides of partition. Contractor advised to reschedule when corrections were made and not to cover partition until inspection was approved.
01/31/2025 BULD - Electrical Clearance N/A Not Applicable
01/31/2025 COT - HCBU - Building Final N/A Not Ready
01/31/2025 COT - HCBU - CofO N/A Not Ready
01/31/2025 COT - HCEL - Electrical Final N/A Not Ready
PDSD Heavy Commercial Building Division Pre-Construction Meeting N/A Requested
01/31/2025 COT - HCBU - TCO N/A Not Ready

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0824-01585
Permit Description: Interior Remodel
Total Completed Inspections - 12
Date Description Inspector Results Comments
12/24/2024 COT - BULD - SWG Clearance Passed 12-24-24, verified pressure test. Clearance issued to Southwest Gas Co.
12/24/2024 COT - FCON - Alarm - Final Passed no alarm work was done
12/24/2024 ENGR Engineering Final Passed
12/24/2024 TRSP - ROW - Final/Close-Out Passed
12/24/2024 COT - FCON - Hood System - Final Passed nothing changed under the hood
12/24/2024 COT - FCON - Sprinkler - Final Passed no sprinkler work was done.
12/24/2024 COT - LCPL - Gas Pressure Test Passed 12-24-24, verified pressure test. Clearance issued to Southwest Gas Co.
01/03/2025 COT - HCEL - Electrical Progress Passed
01/31/2025 COT - HCBU - Building Progress Passed
01/31/2025 COT - HCEL - Electrical Intermediate Passed
01/31/2025 COT - HCBU - Building Above Ceiling Passed
01/31/2025 COT - HCEL - Electrical Above Ceiling Passed