Inspection Status: Partial Pass
Inspection History: COT - HCBU - Building Progress
| Date |
Description |
Inspector |
Results |
Comments |
| 01/03/2025 |
COT - HCBU - Building Progress |
|
Partial Pass |
|
| 01/31/2025 |
COT - HCBU - Building Progress |
|
Passed |
|
| 12/24/2024 |
COT - HCBU - Building Progress |
|
Re-inspection required |
12-24-24, contractor requested that I inspect interior partition located just inside main entrance. Partition had already been covered so I couldn't verify shot pins at 32" o/c but I noted that partition was not installed per approved plans. Missing 5/8" type x drywall on both sides of partition. Contractor advised to reschedule when corrections were made and not to cover partition until inspection was approved. |