Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Commercial Building
Address NEW:
10155 E GOLF LINKS RD
Apply Date:
08/02/2023
Applicant:
Description:
New Storage Facility

Permit Reviews

Permit Number - TC-COM-0823-01889
Permit Status: Inspections
Permit Description: New Storage Facility
Start Date Submittal Complete Date Status  
06/27/2024 COMMERCIAL REVIEW - FULL v.3 07/08/2024 APPROVED Review Details
08/26/2025 COMMERCIAL REVIEW - FULL REVISION v.1 09/17/2025 APPROVED Review Details
08/03/2023 COMMERCIAL REVIEW - FULL v.1 03/01/2024 REQUIRES RESUBMIT Review Details
04/03/2024 COMMERCIAL REVIEW - FULL v.2 06/26/2024 REQUIRES RESUBMIT Review Details
07/08/2024 RESTAMP - COMMERCIAL v.1 07/15/2024 APPROVED Review Details
02/06/2025 COMMERCIAL REVIEW - FULL v.1 02/11/2025 REQUIRES RESUBMIT Review Details
02/21/2025 COMMERCIAL REVIEW - FULL v.2 03/10/2025 REQUIRES RESUBMIT Review Details
04/07/2025 COMMERCIAL REVIEW - FULL v.3 04/15/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0823-01889
Permit Status: Inspections
Permit Description: New Storage Facility
Total Outstanding Activity Conditions - 16
Date Name
02/04/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/23/2024 AIR BALANCING REPORT IS REQUIRED.
04/23/2024 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
04/23/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
04/23/2024 Elevator Designs must be submitted and approved prior to ...
04/23/2024 ELEVATOR INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED.
04/23/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
04/23/2024 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
04/23/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
04/23/2024 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
04/23/2024 Masonry Inspection Report submittal review is required.
04/23/2024 Post-Installed Anchor Inspection Report is required.
04/23/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
04/23/2024 Stair Designs must be submitted and approved prior to...
04/23/2024 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
04/23/2024 WATER STERILIZATION REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0823-01889
Permit Status: Inspections
Permit Description: New Storage Facility
Date Description Comments
04/15/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
04/07/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0823-01889
Permite Description: New Storage Facility
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
10/22/2025 BULD - Electrical Clearance N/A Partial Pass
10/24/2025 COT - HCBU - Excavation/Rebar/Zoning N/A Partial Pass North end footing.
11/03/2025 COT - HCEL - Electrical Underground N/A Partial Pass Partial pass for underground plumbing in central area. Partial pass for north retaining wall and east footing wall, ok to proceed. Partial pass for underground electric at each elevator and mechanical room
11/03/2025 COT - HCPL - Plumbing Intermediate N/A Partial Pass Partial pass for underground plumbing in central area. Partial pass for north retaining wall and east footing wall, ok to proceed. Partial pass for underground electric at each elevator and mechanical room
11/03/2025 COT - HCPL - Sewer N/A Partial Pass Partial pass for underground plumbing in central area. Partial pass for north retaining wall and east footing wall, ok to proceed. Partial pass for underground electric at each elevator and mechanical room
11/19/2025 COT - HCBU - Stem Wall/Retaining Wall N/A Partial Pass Elevator One.
11/19/2025 COT - HCBU - Preslab N/A Partial Pass Interior pad footings West side.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0823-01889
Permit Description: New Storage Facility
Total Completed Inspections - 1
Date Description Inspector Results Comments
11/06/2025 COT - HCEL - Electrical Underground Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-REV_STAIR REVISION_V1.PDF DOCUMENTS VIEW
REV NARRATIVE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CAP GOLF LINKS GEOTECH REPORT_V2.PDF DOCUMENTS VIEW
CAP GOLF LINKS STRUCTURAL CALCS_V2.PDF DOCUMENTS VIEW
CONS-PLAN SET_V3.PDF DOCUMENTS VIEW
SIC__V2.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW