Permit Details

Status:
Needs Resubmittal
Type:
Commercial Building
Address NEW:
7002 E BROADWAY BL
Apply Date:
05/08/2026
Applicant:
Kyle Zimmermann
Description:
-Install (1) 125amp-220volt dedicated circuit. Remove existing disconnect under blanked off meter base due to age and condition. Install (1) 125amp-220volt general duty disconnect at existing location. Install surface mounted conduit and wiring from new disconnect up along wall, through rooftop, along rooftop properly suspended on unistrut, along metal beam over patio, down east side of building to new sub-panel location. Install (3) #3THHN and (1) #6THHN copper wires. Install (1) Eaton Cutler Hammer 125amp-220volt exterior sub-panel on east side of building. Install (1) ground bar. New sub-panel installation to be used for additional storage containers in the future. Install (2) 100amp fuses in new disconnect to operate new sub-panel. Tucson Electric Power to set new meter upon completion and clearance/final of permit as per Shane Young, TEP field tech (520)279-9978. -Obtain permit, open applications, and coordinate inspections with City of Tucson and Tucson Electric Power.

Permit Reviews

Permit Number - TC-COM-0526-00681
Permit Status: Needs resubmittal
Permit Description: -Install (1) 125amp-220volt dedicated circuit. Remove existing disconnect under blanked off meter base due to age and condition. Install (1) 125amp-220volt general duty disconnect at existing location. Install surface mounted conduit and wiring from new disconnect up along wall, through rooftop, along rooftop properly suspended on unistrut, along metal beam over patio, down east side of building to new sub-panel location. Install (3) #3THHN and (1) #6THHN copper wires. Install (1) Eaton Cutler Hammer 125amp-220volt exterior sub-panel on east side of building. Install (1) ground bar. New sub-panel installation to be used for additional storage containers in the future. Install (2) 100amp fuses in new disconnect to operate new sub-panel. Tucson Electric Power to set new meter upon completion and clearance/final of permit as per Shane Young, TEP field tech (520)279-9978. -Obtain permit, open applications, and coordinate inspections with City of Tucson and Tucson Electric Power.
Start Date Submittal Complete Date Status  
05/08/2026 COMMERCIAL PDSD SIMPLE REVIEW v.1 05/26/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0526-00681
Permit Status: Needs resubmittal
Permit Description: -Install (1) 125amp-220volt dedicated circuit. Remove existing disconnect under blanked off meter base due to age and condition. Install (1) 125amp-220volt general duty disconnect at existing location. Install surface mounted conduit and wiring from new disconnect up along wall, through rooftop, along rooftop properly suspended on unistrut, along metal beam over patio, down east side of building to new sub-panel location. Install (3) #3THHN and (1) #6THHN copper wires. Install (1) Eaton Cutler Hammer 125amp-220volt exterior sub-panel on east side of building. Install (1) ground bar. New sub-panel installation to be used for additional storage containers in the future. Install (2) 100amp fuses in new disconnect to operate new sub-panel. Tucson Electric Power to set new meter upon completion and clearance/final of permit as per Shane Young, TEP field tech (520)279-9978. -Obtain permit, open applications, and coordinate inspections with City of Tucson and Tucson Electric Power.
Total Outstanding Activity Conditions - 1
Date Name
05/08/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Documents

File Name Document Type  
7002 E BROADWAY_V1.PDF DOCUMENTS VIEW