Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
In Review
Type:
Commercial Building
Address:
4811 E GRANT RD
Apply Date:
05/08/2024
Applicant:
burak bekat
Description:
Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag

Permit Reviews

Permit Number - TC-COM-0524-00894
Permit Status: In review
Permit Description: Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag
Start Date Submittal Complete Date Status  
12/12/2024 COMMERCIAL REVIEW - FULL v.1 N/A IN REVIEW Review Details
08/13/2024 RESTAMP - COMMERCIAL v.1 08/15/2024 APPROVED Review Details
07/02/2024 COMMERCIAL REVIEW - FULL v.2 08/13/2024 APPROVED Review Details
05/10/2024 COMMERCIAL REVIEW - FULL v.1 06/17/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0524-00894
Permit Status: In review
Permit Description: Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag
Total Outstanding Activity Conditions - 6
Date Name
06/12/2024 AIR BALANCING REPORT IS REQUIRED.
06/12/2024 WATER STERILIZATION REPORT IS REQUIRED.
08/06/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/06/2024 SPECIAL INSPECTION FOR STEEL CONSTRUCTION IS REQUIRED.
08/08/2024 Guard designs at projector mezzanines shown . Designs must be submitted and approved, then installed prior to Final Inspections
08/08/2024 Plans to be revised to show Laser Tag room #114 comply with IBC Section 411. Approved directional exit markings shall be provided. Where mirrors, mazes or other designs are utilized that disguise the path of egress travel such that they are not apparent, approved and listed low-level exit signs that comply with Section 1013.5, and directional path markings listed in accordance with UL 1994, shall be provided and located not more than 8 inches (203 mm) above the walking surface and on or near the path of egress travel. Such markings shall become visible in an emergency. The directional exit marking shall be activated by the automatic fire detection system and the automatic sprinkler system in accordance with Section 907.2.11.

Conditions

Permit Number - TC-COM-0524-00894
Permit Status: In review
Permit Description: Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag
Date Description Comments
05/10/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
08/06/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: In Review
Permit Number: TC-COM-0524-00894
Permite Description: Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
10/08/2024 COT - LCBU - Framing N/A Partial Pass South Barge wall.
10/14/2024 COT - HCBU - Interior Shear Bracing N/A Partial Pass Third layer on West Fire Wall.
12/04/2024 COT - LCEL - Electrical Above Ceiling N/A Partial Pass Rooms #107,#108,#109,#110,#111. Approved okay to proceed progress areas. 12/4/2024
12/04/2024 COT - LCME - Mechanical Above Ceiling N/A Partial Pass Rooms #107,#108,#109,#110,#111. Approved okay to proceed progress areas. 12/4/2024
11/22/2024 COT - LCBU - Masonry Pregrout N/A Canceled Canceled per contractor. 11/22/2024
12/17/2024 BULD - Electrical Clearance N/A Not Applicable
12/17/2024 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: In Review
Permit Number: TC-COM-0524-00894
Permit Description: Tenant improvement for Roadies, a Family Entertainment Center with a bowling alley, arcade, axe throwing and laser tag
Total Completed Inspections - 13
Date Description Inspector Results Comments
08/27/2024 COT - LCPL - Rough Soil Passed
08/28/2024 COT - LCEL - Electrical Underground Passed
09/10/2024 COT - LCEL - Electrical Intermediate Passed
09/10/2024 COT - LCBU - Excavation/Rebar/Zoning Passed
09/10/2024 COT - LCBU - Preslab Passed
09/06/2024 COT - HCPL - Rough Soil Passed
11/13/2024 COT - LCBU - Framing Passed
11/13/2024 COT - LCME - Mechanical Intermediate Passed
11/13/2024 COT - LCEL - Electrical Progress Passed
11/13/2024 COT - LCPL - Plumbing Intermediate Passed
11/13/2024 COT - HCBU - Interior Shear Bracing Passed
11/19/2024 COT - LCBU - Roof Nailing Passed
12/04/2024 COT - LCBU - Masonry Pregrout Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2-PLAN_SET_V2.PDF DOCUMENTS VIEW
2-SPECIAL_INSPECTION_CERTIFICATE-2024-07-01_V1.PDF DOCUMENTS VIEW