Permit: TC-COM-0426-00482
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
2908 N CAMPBELL AV
Address NEW:
2908 N CAMPBELL AV
Apply Date:
04/07/2026
Applicant:
Deborah Sylva
Description:
THE SCOPE OF WORK PROPOSED WITH THIS SUBMITTAL IS THE INTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,000 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Permit Reviews
Permit Number - TC-COM-0426-00482
Permit Status: Complete
Permit Description: THE SCOPE OF WORK PROPOSED WITH THIS SUBMITTAL IS THE INTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,000 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/06/2026 | COMMERCIAL REVIEW - LIMITED v.2 | 05/22/2026 | APPROVED |
| 07/23/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/27/2026 | APPROVED |
| 04/09/2026 | COMMERCIAL REVIEW - LIMITED v.1 | 05/04/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0426-00482
Permit Status: Complete
Permit Description: THE SCOPE OF WORK PROPOSED WITH THIS SUBMITTAL IS THE INTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,000 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
| Date | Description | Comments |
|---|---|---|
| 04/16/2026 | AIR BALANCING REPORT IS REQUIRED. | |
| 04/09/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 04/09/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/16/2026 | WATER STERILIZATION REPORT IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-0426-00482
Permite Description: THE SCOPE OF WORK PROPOSED WITH THIS SUBMITTAL IS THE INTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,000 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2026 | COT - LCEL - Electrical Intermediate | N/A | Re-inspection required | 6/11/26: Not ready, missing circuit runs to multiple receptacles, all removed receptacles shall be submitted on a revision, |
| 06/11/2026 | COT - LCPL - Plumbing Intermediate | N/A | Re-inspection required | 6/11/26: 3/4" and larger hot water piping shall be insulated, properly support pex (32" horizontal and 48" vertical), DWV must be properly supported horizontal 4' o.c, 18" of copper required at water heater connection before transitioning to pex,. |
| 07/30/2026 | BULD - Electrical Clearance | N/A | Not Applicable | |
| 07/30/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0426-00482
Permit Description: THE SCOPE OF WORK PROPOSED WITH THIS SUBMITTAL IS THE INTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,000 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/27/2026 | COT - LCPL - Rough Soil | Passed | ||
| 05/29/2026 | COT - LCBU - Preslab | Passed | please glue cap all abandoned lines under slab no Jim caps allowed | |
| 06/11/2026 | COT - LCBU - Framing | Passed | ||
| 06/13/2026 | COT - LCEL - Electrical Intermediate | Passed | ||
| 06/13/2026 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 07/10/2026 | COT - LCBU - Building Above Ceiling | Passed | ||
| 07/10/2026 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 07/10/2026 | COT - LCME - Mechanical Intermediate | Passed | ||
| 07/27/2026 | COT - FCON - Fire - Final | Passed | ||
| 07/27/2026 | COT - LCME - Mechanical Final | Passed | ||
| 07/28/2026 | COT - LCBU - Building Final | Passed | ||
| 07/28/2026 | COT - LCEL - Electrical Final | Passed | ||
| 07/28/2026 | COT - LCPL - Plumbing Final | Passed |