Permit: TC-COM-0323-00938
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
5919 E BROADWAY BL
Address NEW:
5919 E BROADWAY BL
Apply Date:
03/31/2023
Applicant:
Amy Hodgson
Description:
Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
Permit Reviews
Permit Number - TC-COM-0323-00938
Permit Status: Issued
Permit Description: Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/05/2023 | COMMERCIAL REVIEW - FULL v.2 | 06/05/2023 | APPROVED |
| 09/21/2023 | COMMERCIAL REVIEW - FULL v.1 | 02/28/2024 | REQUIRES RESUBMIT |
| 03/28/2024 | COMMERCIAL REVIEW - FULL v.2 | 06/27/2024 | APPROVED |
| 06/27/2024 | RESTAMP - COMMERCIAL v.1 | 06/27/2024 | APPROVED |
| 04/05/2023 | COMMERCIAL REVIEW - FULL v.1 | 05/26/2023 | REQUIRES RESUBMIT |
| 06/05/2023 | RESTAMP - COMMERCIAL v.1 | 06/12/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0323-00938
Permit Status: Issued
Permit Description: Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 05/26/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
| 05/26/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 05/26/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 05/26/2023 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 05/26/2023 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 05/26/2023 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 05/26/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-COM-0323-00938
Permit Status: Issued
Permit Description: Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
| Date | Description | Comments |
|---|---|---|
| 05/26/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. | |
| 05/26/2023 | Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0323-00938
Permite Description: Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2023 | COT - LCBU - Building Progress | N/A | Partial Pass | 7/11/23: Met Felipe at site and reviewed approved drawings and I pointed out that a 3rd party inspector will be required for cutting a large opening into the rear CMU wall. |
| 07/25/2023 | COT - HCBU - Framing | N/A | Re-inspection required | |
| 09/14/2023 | COT - HCEL - Electrical Above Ceiling | N/A | Partial Pass | 9/13/23: remove all ceiling tiles in areas that require above ceiling inspection. Approved plans are required on site at all times. 9/14/23: above ceiling approved in wet spa display room on east wall. |
| 09/26/2023 | COT - HCEL - Electrical Final | N/A | Partial Pass | 9/26/23: electric complete except for retyping panel schedules |
| 10/03/2023 | ENGR Engineering Final | N/A | Not Ready | Additional ramp has been added to the exterior of the building, which blocks the pedestrian pathway from the other portions of the building to the trash and closure. This ramp needs to be submitted and approved by engineering and zoning, was for it can be inspected for the site. |
| 10/13/2023 | COT - FCON - Fire - Final | N/A | Partial Pass | Exit sign in back hall way needs to be repaired, Exit sign in backroom needs to be repaired, Knox box, Knox FDC caps. Fire sprinkler work needs to be inspected, riser needs annual inspection. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0323-00938
Permit Description: Interior tenant improvement for a new retail tenant Bullfrog Spas to move into an existing space. Scope to include new overhead door and minor electrical upgrades.
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2023 | COT - HCEL - Electrical Intermediate | Passed | Electrical rough-in is complete. Okay to cover walls with drywall. | |
| 07/28/2023 | COT - HCBU - Framing | Passed | Bracing has been installed from rafters to top of wall on center wall. Okay to install drywall throughout building. | |
| 10/11/2023 | COT - HCBU - Excavation/Rebar/Zoning | Passed | ||
| 10/13/2023 | COT - FCON - Alarm - Final | Passed | Approved on 10/02/23 on permit TF-FCP-0923-01078. | |
| 10/17/2023 | COT - HCBU - Building Final | Passed | Recommend Level 4 TCO. | |
| 11/14/2023 | COT - FCON - Fire - Final | Passed |