Permit: TC-COM-0225-00299
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
3480 E BRITANNIA DR
Address NEW:
3480 E BRITANNIA DR
Apply Date:
02/12/2025
Applicant:
Janice Lohman
Description:
Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
Permit Reviews
Permit Number - TC-COM-0225-00299
Permit Status: Inspections
Permit Description: Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/13/2025 | COMMERCIAL REVIEW - FULL v.1 | 03/17/2025 | REQUIRES RESUBMIT |
| 04/15/2025 | COMMERCIAL REVIEW - FULL v.3 | 04/18/2025 | APPROVED |
| 03/18/2025 | COMMERCIAL REVIEW - FULL v.2 | 04/07/2025 | REQUIRES RESUBMIT |
| 04/18/2025 | RESTAMP - COMMERCIAL v.1 | 04/22/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0225-00299
Permit Status: Inspections
Permit Description: Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 02/28/2025 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 02/28/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 02/28/2025 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 02/28/2025 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 02/28/2025 | SPECIAL INSPECTION FOR INSULATING CONCRETE FILL IS REQUIRED. |
| 02/28/2025 | ??? Designs must be submitted and approved prior to ... |
Conditions
Permit Number - TC-COM-0225-00299
Permit Status: Inspections
Permit Description: Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
| Date | Description | Comments |
|---|---|---|
| 02/13/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 02/13/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0225-00299
Permite Description: Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2025 | COT - HCBU - Preslab | N/A | Partial Pass | 5/2/25: Pour back at bathroom area per approved plans ok for concrete placement. |
| 06/06/2025 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | 6-6-25: verified in wall domestic and DWV at breakroom bathrooms under test and per plans. Copper lines must be insulated and wrapped and will be verified prior to covering lids. Okay to proceed with construction at progress areas. |
| 05/20/2025 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | Assembly rooms #1,#2,& #3. Corridor south end. (Man trap # 112) electrical in wall approved. Okay to proceed progress areas. 5/20/2025 |
| 07/18/2025 | COT - HCBU - Building Above Ceiling | N/A | Not Ready | 7-18-25: this inspection will be verified at finals. |
| 07/18/2025 | COT - HCEL - Electrical Above Ceiling | N/A | Partial Pass | 7-18-25: electrical above ceiling at room's 117, 118, 120, 121 approved. Okay to continue with construction at hard lid areas. |
| 07/18/2025 | COT - HCME - Mechanical Above Ceiling | N/A | Partial Pass | 7-18-25: partial pass for mechanical above ceiling at room's 117, 118, 120, 121. An RFI reflecting future chase & re-routing of mechanical will be required. However, Okay to continue with construction at hard lid areas as access will still be available. |
| 07/18/2025 | COT - HCPL - Plumbing Above Ceiling | N/A | Partial Pass | 7-18-25: plumbing above ceiling at room's 117, 118, 120, 121 verified per plans. Okay to proceed with hard lids. |
| 05/02/2025 | COT - HCBU - Interior Shear Bracing | N/A | Partial Pass | 4/29/25: Progress inspection on Assembly rooms (4,5,6) ok to proceed with one-side. 5/2/25: Progress inspection on Assembly rooms (4,5,6) ok to proceed with one-side. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0225-00299
Permit Description: Interior Renovation of existing space for new office and assembly space. No exterior work or changes to exterior.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2025 | COT - HCPL - Rough Soil | Passed | 4/29/25: plumbing underground at rooms (111,117,118,119,120,121), ok to proceed with backfill and prep for concrete placement. | |
| 05/02/2025 | COT - HCBU - Roof Nailing | Passed | ||
| 06/27/2025 | COT - HCBU - Framing | Passed |