Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0223-00696
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
4880 E 29TH ST BLDG 1
Address NEW:
4880 E 29TH ST BLDG 1
Apply Date:
02/23/2023
Applicant:
Kevin zuniga
Description:
Remove existing pool interior, demo existing deck, new plumbing, new electrical, new equipment, new floor depth change, new deck and interior finish
Permit Reviews
Permit Number - TC-COM-0223-00696
Permit Status: Complete
Permit Description: Remove existing pool interior, demo existing deck, new plumbing, new electrical, new equipment, new floor depth change, new deck and interior finish
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/09/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 10/09/2024 | APPROVED |
| 06/28/2023 | COMMERCIAL REVIEW - FULL v.5 | 07/31/2023 | APPROVED |
| 08/28/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/01/2023 | REQUIRES RESUBMIT |
| 04/17/2023 | COMMERCIAL REVIEW - FULL v.2 | 04/17/2023 | REQUIRES RESUBMIT |
| 05/22/2023 | COMMERCIAL REVIEW - FULL v.4 | 06/12/2023 | REQUIRES RESUBMIT |
| 07/31/2023 | RESTAMP - COMMERCIAL v.1 | 07/31/2023 | APPROVED |
| 03/02/2023 | COMMERCIAL REVIEW - FULL v.1 | 04/12/2023 | REQUIRES RESUBMIT |
| 04/20/2023 | COMMERCIAL REVIEW - FULL v.3 | 05/19/2023 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0223-00696
Permit Status: Complete
Permit Description: Remove existing pool interior, demo existing deck, new plumbing, new electrical, new equipment, new floor depth change, new deck and interior finish
| Date | Description | Comments |
|---|---|---|
| 03/28/2023 | Please contact Pima County Addressing to resolve your addressing issue related to TC-COM-0223-00696. Addressing@pima.gov or 520-724-9512 | |
| 04/11/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-0223-00696
Permite Description: Remove existing pool interior, demo existing deck, new plumbing, new electrical, new equipment, new floor depth change, new deck and interior finish
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2023 | Pool/Spa - Electric | N/A | Not Ready | |
| 06/27/2025 | Pool/Spa - Final/Barrier | N/A | Re-inspection required | 6/27/25: revision required regarding site location of pool. hand rails and step ladders not set in place at time of final inspection. exterior GFCI receptacles missing at exterior throughout,Emergency disconnect required at equipment room, B-vent for heaters require proper clearance from combustibles, all equipment must be properly secured to foundation, will need access into office/mail room to ensure all doors/openings meet requirements. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0223-00696
Permit Description: Remove existing pool interior, demo existing deck, new plumbing, new electrical, new equipment, new floor depth change, new deck and interior finish
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2023 | Pool/Spa - Bonding Grip | Passed | Ground wire around spa is connected to main ground wire from pool equipment. Okay to proceed with spa repair. | |
| 11/01/2023 | Pool/Spa - Electric | Passed | ||
| 11/01/2023 | Pool/Spa - Gas | Passed | ||
| 11/01/2023 | Pool/Spa - Plumbing | Passed | Plumbing pipes are properly connected to spa. Okay to proceed with spa repair. | |
| 11/01/2023 | Pool/Spa - Pre-Gunite | Passed | Okay to proceed with gunite application on spa. | |
| 11/01/2023 | Pool/Spa - Heater | Passed | ||
| 08/07/2025 | Pool/Spa - Final/Barrier | Passed |