Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Approved - Awaiting Customer Attention
Type:
Commercial Building
Address:
24 N NORRIS AV
Address NEW:
24 N NORRIS AV
Apply Date:
01/24/2024
Applicant:
Bret West
Description:
TUCSON FIRE STATION NO. 3 IS A NEW TWO STORY FIRE STATION OF 15,000 SQUARE FEET. THE PROPOSED FACILITY INCLUDES FOUR BAYS, 11 DORMITORIES, FITNESS ROOM AND WORK/ LIVING SPACE. THE SITE IS 0.85± ACRES LOCATED ON THE NORTHEAST CORNER OF BROADWAY ROAD AND NORRIS AVENUE. FIRE STATION NO. 3 IS DESIGNED IN ACCORDANCE WITH THE CITY OF TUCSON'S BUILDING DESIGN AND CONSTRUCTION STANDARDS AND THE CURRENT ADOPTED BUILDING CODES. THE DESIGN WILL INCORPORATE ENVIRONMENTAL DESIGN PRINCIPLES TO REDUCE ENERGY CONSUMPTION AND WATER PRESERVATION IN ORDER TO ACHIEVE A LEED SILVER CERTIFICATION. THE BUILDING ENVELOPE IS COMPOSED OF CONCRETE MASONRY BLOCK UNITS WITH EXPOSED BLOCK, AND METAL PANEL FINISHES. FLAT (LOW SLOPE) ROOFS WILL BE UTILIZED TO DEFINE MASSING AND ALLOW FOR REQUIRED MECHANICAL SCREENING.

Permit Reviews

Permit Number - TC-COM-0124-00162
Permit Status: Approved - awaiting customer attention
Permit Description: TUCSON FIRE STATION NO. 3 IS A NEW TWO STORY FIRE STATION OF 15,000 SQUARE FEET. THE PROPOSED FACILITY INCLUDES FOUR BAYS, 11 DORMITORIES, FITNESS ROOM AND WORK/ LIVING SPACE. THE SITE IS 0.85± ACRES LOCATED ON THE NORTHEAST CORNER OF BROADWAY ROAD AND NORRIS AVENUE. FIRE STATION NO. 3 IS DESIGNED IN ACCORDANCE WITH THE CITY OF TUCSON'S BUILDING DESIGN AND CONSTRUCTION STANDARDS AND THE CURRENT ADOPTED BUILDING CODES. THE DESIGN WILL INCORPORATE ENVIRONMENTAL DESIGN PRINCIPLES TO REDUCE ENERGY CONSUMPTION AND WATER PRESERVATION IN ORDER TO ACHIEVE A LEED SILVER CERTIFICATION. THE BUILDING ENVELOPE IS COMPOSED OF CONCRETE MASONRY BLOCK UNITS WITH EXPOSED BLOCK, AND METAL PANEL FINISHES. FLAT (LOW SLOPE) ROOFS WILL BE UTILIZED TO DEFINE MASSING AND ALLOW FOR REQUIRED MECHANICAL SCREENING.
Start Date Submittal Complete Date Status  
01/29/2024 COMMERCIAL REVIEW - FULL v.1 02/26/2024 REQUIRES RESUBMIT Review Details
09/25/2026 ADMINISTRATIVE v.1 09/25/2026 REQUIRES RESUBMIT Review Details
08/17/2026 COMMERCIAL REVIEW - FULL v.2 08/26/2026 REQUIRES RESUBMIT Review Details
09/17/2026 COMMERCIAL REVIEW - FULL v.3 09/25/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0124-00162
Permit Status: Approved - awaiting customer attention
Permit Description: TUCSON FIRE STATION NO. 3 IS A NEW TWO STORY FIRE STATION OF 15,000 SQUARE FEET. THE PROPOSED FACILITY INCLUDES FOUR BAYS, 11 DORMITORIES, FITNESS ROOM AND WORK/ LIVING SPACE. THE SITE IS 0.85± ACRES LOCATED ON THE NORTHEAST CORNER OF BROADWAY ROAD AND NORRIS AVENUE. FIRE STATION NO. 3 IS DESIGNED IN ACCORDANCE WITH THE CITY OF TUCSON'S BUILDING DESIGN AND CONSTRUCTION STANDARDS AND THE CURRENT ADOPTED BUILDING CODES. THE DESIGN WILL INCORPORATE ENVIRONMENTAL DESIGN PRINCIPLES TO REDUCE ENERGY CONSUMPTION AND WATER PRESERVATION IN ORDER TO ACHIEVE A LEED SILVER CERTIFICATION. THE BUILDING ENVELOPE IS COMPOSED OF CONCRETE MASONRY BLOCK UNITS WITH EXPOSED BLOCK, AND METAL PANEL FINISHES. FLAT (LOW SLOPE) ROOFS WILL BE UTILIZED TO DEFINE MASSING AND ALLOW FOR REQUIRED MECHANICAL SCREENING.
Total Outstanding Activity Conditions - 10
Date Name
09/22/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
09/22/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/22/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
09/22/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
09/22/2026 Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required.
09/22/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
09/23/2026 Prior to Final - Required Documents - AIR BALANCING REPORT IS REQUIRED.
09/23/2026 Prior to Final - Required Documents - Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
09/23/2026 Prior to Issuance - Special Inspections - Separate submittal to PC Industrial Wastewater Control is required for new interceptors and separators. Contact Kelsey.McMonagle@pima.gov or Adam.DeLaTorre@pima.gov for review and assessment of the proposed grease interceptor.
09/23/2026 WATER STERILIZATION REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0124-00162
Permit Status: Approved - awaiting customer attention
Permit Description: TUCSON FIRE STATION NO. 3 IS A NEW TWO STORY FIRE STATION OF 15,000 SQUARE FEET. THE PROPOSED FACILITY INCLUDES FOUR BAYS, 11 DORMITORIES, FITNESS ROOM AND WORK/ LIVING SPACE. THE SITE IS 0.85± ACRES LOCATED ON THE NORTHEAST CORNER OF BROADWAY ROAD AND NORRIS AVENUE. FIRE STATION NO. 3 IS DESIGNED IN ACCORDANCE WITH THE CITY OF TUCSON'S BUILDING DESIGN AND CONSTRUCTION STANDARDS AND THE CURRENT ADOPTED BUILDING CODES. THE DESIGN WILL INCORPORATE ENVIRONMENTAL DESIGN PRINCIPLES TO REDUCE ENERGY CONSUMPTION AND WATER PRESERVATION IN ORDER TO ACHIEVE A LEED SILVER CERTIFICATION. THE BUILDING ENVELOPE IS COMPOSED OF CONCRETE MASONRY BLOCK UNITS WITH EXPOSED BLOCK, AND METAL PANEL FINISHES. FLAT (LOW SLOPE) ROOFS WILL BE UTILIZED TO DEFINE MASSING AND ALLOW FOR REQUIRED MECHANICAL SCREENING.
Date Description Comments
09/22/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.