Permit: T99MH00608
Permit Details
Apply Date:
11/19/1999
Applicant:
TROY STAATS
Description:
MOBILE HOME:SET UP
Outstanding Inspections
Permit Status: Expired
Permit Number: T99MH00608
Permite Description: MOBILE HOME:SET UP
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
MOBILE HOME ACCESSORIES | N/A | Not Inspected | ||
MOBILE HOME FINAL | N/A | Not Inspected | ||
12/17/1999 | MOBILE HOME ELECTRICAL | N/A | Correction Required | ADDTL COMMS - 1. PROVIDE COMPRESSION CONNECTORS ON E.M.T. CONDUIT INTO PEDESTAL. 2. PVC CONDUIT IS NOT MARKED SCHD.80 OR AS APPROVED FOR EXTERIOR. (EXTRA HEAVY DUTY) MAIN LINES INTO PEDESTAL. 3. TAPE NEUTRAL COND. AT PEDESTAL AND AT INTERIOR MAIN PANEL WITH WHITE TAPE AND VERIFY ITIS THE SAME CONDUCTOR. 4. EXPOSE THE GROUND RODS AND THE GROUNDING ELECTRODE CONDUCTOR. |
Completed Inspections
Permit Status: Expired
Permit Number: T99MH00608
Permit Description: MOBILE HOME:SET UP
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/17/1999 | MOBILE HOME PLUMBING | MTESTER | Approved | IVRS - Inspection 0330* |
12/17/1999 | MOBILE HOME PLUMBING | MTESTER | Approved | ADDTL COMMS - SEWER LINE NOT FILLED WITH WATER. WATER SUPPLY NOT ON. |
12/17/1999 | MOBILE HOME UNDERGROUND GAS | MTESTER | Approved | ADDTL COMMS - GAS PIPING AND PRESSURE TEST OKAY. |