Applicant:
GRUBB TODD R
Description:
UPGRADE:ELECTRIC 100 AMP TO 200 AMP

Completed Inspections

Permit Status: Final
Permit Number: T99EL03006
Permit Description: UPGRADE:ELECTRIC 100 AMP TO 200 AMP
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/29/1999 ELECTRIC - FINAL RSUBA Approved IVRS - Inspection 0999*
12/29/1999 ELECTRIC - FINAL RSUBA Approved ADDTL COMMS - 1. I.D. NEUTRAL WHITE 2. PLASTIC ADDRESS NOT ACCEPTABLE PER T.E.P. (USE METAL TAG OR OTHER UTILITY APPROVED METHOD) 3. NEED NAME OR ELEC, CONTRACTOR DOING THIS JOB LEAVE NAME AND LIC# AT 791-5550 X136 4. SERVICE MOUNTED TOO HIGH METER BASE IS NOT TO EXCEED 63 TO CENTER ALSO MAIN BREAKER CANT BE HIGHER THAN 6 OER B.E.C. 380-8 5. INSTALL #4 WATER BOND FOR 200 AMP SERVICE

Documents

File Name Document Type  
None DOCUMENTS VIEW