RECONNECT:ELECTRIC:SFR
Completed Inspections
Permit Status: Final
Permit Number: T99EL02904
Permit Description: RECONNECT:ELECTRIC:SFR
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/1999 | ELECTRIC - RECONNECT | RSUBA | Approved | IVRS - Inspection 0999* |
| 11/10/1999 | ELECTRIC - RECONNECT | RSUBA | Approved | ADDTL COMMS - 1. 3 WIRE RECEPTACLES NOT ALLOWED ON NON GROUNDING CIRCUIT UNLESS GFCI PROTECTED 2. INSTALL SMOKE DETECTOR IN HALL CEILING 3. PROPERLY WIRE FLOOR FIXTURES ABOVE KITCHEN SINK AREA 4. JUNCTION EXPOSED WIRES AT SINK LOCATION 5. INSTALL MISSING COVER AT J-BOX (CEILING) AT SOUTH EAST BEDROOM 6. PROPERLY WIRE KITCHEN CEILING FIXTURE 7. INSTALL MISSING RECEPTACLE SOUTH WEST ROOM 8. JUNCTION OPEN SPLICE IN WORKSHOP (ABOVE THE LIGHT SWITCH) 9. ATTACH LOOSE J-BOX (S.W. CORNER OF HOUSE OUTDOORS) 10. REMOVE U.F. WIRE AT EAST GATE OR WIRE PER CODE 11. NEED PERMITS FOR NEW WATER HEATER AND FURNACE |