Inspection Status: Correction Required
Inspection History: ELECTRIC - RECONNECT
Permit Number - T99EL02904
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/1999 | ELECTRIC - RECONNECT | Correction Required | ADDTL COMMS - 1. 3 WIRE RECEPTACLES NOT ALLOWED ON NON GROUNDING CIRCUIT UNLESS GFCI PROTECTED 2. INSTALL SMOKE DETECTOR IN HALL CEILING 3. PROPERLY WIRE FLOOR FIXTURES ABOVE KITCHEN SINK AREA 4. JUNCTION EXPOSED WIRES AT SINK LOCATION 5. INSTALL MISSING COVER AT J-BOX (CEILING) AT SOUTH EAST BEDROOM 6. PROPERLY WIRE KITCHEN CEILING FIXTURE 7. INSTALL MISSING RECEPTACLE SOUTH WEST ROOM 8. JUNCTION OPEN SPLICE IN WORKSHOP (ABOVE THE LIGHT SWITCH) 9. ATTACH LOOSE J-BOX (S.W. CORNER OF HOUSE OUTDOORS) 10. REMOVE U.F. WIRE AT EAST GATE OR WIRE PER CODE 11. NEED PERMITS FOR NEW WATER HEATER AND FURNACE | |
| 11/10/1999 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999* |