Permit: T99CM05918
Permit Details
Apply Date:
12/21/1999
Applicant:
FINOCCHIARC PETE
Description:
ADDITION:CLUBHOUSE & BATH HOUSE
Contractors:
- MANUFACTURED HOUSING COMMUNITY B
Permit Reviews
Permit Number - T99CM05918
Permit Status: C of o
Permit Description: ADDITION:CLUBHOUSE & BATH HOUSE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/20/2001 | REVISION | 08/20/2001 | COMPLETED |
10/24/2000 | REVISION | 02/12/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T99CM05918
Permit Description: ADDITION:CLUBHOUSE & BATH HOUSE
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2000 | BUILDING PRE-SLAB | DWITT | Approved | ADDTL COMMS - EXTEND CONTINUOUS STEEL, TOP AND BOTTOM, TO THE END OF THE FOOTING. |
12/18/2000 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* OK 2 1/2", 2", 1 1/4" PVC CONDUITS FROM BATH HOUSE TO CLUBHOUSE |
12/19/2000 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
12/19/2000 | ROOF NAILING | DWITT | Approved | IVRS - Inspection 0000* |
12/19/2000 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved | IVRS - Inspection 0000* |
12/22/2000 | ELECTRIC - TEMPORARY POLE | MCAPISTR | Approved | IVRS - Inspection 0000* OK TO CLEAR |
02/21/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
02/21/2001 | BUILDING ABOVE CEILING | DWITT | Approved | IVRS - Inspection 0000* |
02/22/2001 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/22/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000* MUST SEE CLOSET RINGS WHEN INSTALLED OK TO DRY WALL |
02/26/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
03/06/2001 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000* NOTE: MUST HAVE REVISED AND APPROVED DRAWING ON SITE SEWER FOR CLUBHOUSE AND BATH HOUSE BEFORE FINAL INSP. OK TO BACKFILL |
03/15/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* 1) RENAIL WHERE PAPER IS BROKEN 2) USE CLIPS AT CORNERS WITH OUT BACKING 3) FINISH THE NAILING |
04/04/2001 | STUCCO MESH | DWITT | Approved | IVRS - Inspection 0000* |
07/31/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
08/08/2001 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000* |
08/08/2001 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*I AM ADVISED BY THE G.C THAT PLANS W/AS BUILT CHANGES ARE BEING PREPARED FOR SUBMITTAL WITHIN NOT MORE THAN 15 DAYS. |
08/17/2001 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000* |
08/20/2001 | ENGINEERING - FINAL | ENGINEER | Approved | |
08/21/2001 | PERMIT FINALED | FIRE | Approved | |
08/21/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
08/21/2001 | FIRE SPKLR - OH PIPING & HYDRO | FIRE | Approved | |
08/21/2001 | FIRE SPKLR - UG PIPING FLUSH | FIRE | Approved |