Permit: T99CM05497
Permit Details
Apply Date:
11/18/1999
Applicant:
FAGIN, EDWARD A
Description:
ADDITION:OFFICE
Architects:
- FAGIN, EDWARD A
Contractors:
- BLUELINE CONSTRUCTION INC
Outstanding Inspections
Permit Status: Closed
Permit Number: T99CM05497
Permite Description: ADDITION:OFFICE
Total Outstanding Inspections - 20
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
| STEM WALL/RETAINING WALL | N/A | Not Inspected | ||
| REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
| EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - ABOVE CEILING | N/A | Not Inspected | ||
| PLUMBING - ABOVE CEILING | N/A | Not Inspected | ||
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| PLUMBING - PROGRESS | N/A | Not Inspected | ||
| MECHANICAL - ABOVE CEILING | N/A | Not Inspected | ||
| MECHANICAL - PROGRESS | N/A | Not Inspected | ||
| FIRE - FINAL | N/A | Not Inspected | ||
| LANDSCAPE - FINAL | N/A | Not Inspected | ||
| SIGN - FINAL | N/A | Not Inspected | ||
| 06/15/2000 | MECHANICAL - INTERMEDIATE | N/A | Correction Required | ADDTL COMMS - 1. CONDENSATE DRAIN RUNS UPHILL NEED 1/8 PER FOOT MIN SLOPE. 2. CONDENSATE DRAIN CORRECTION TO AIR HANDLER IS CONNECTED TO THE WRONG OUTLET USE THREADED PLUGS IN OUTLETS NOT BEING USED. 3. INSULATE REFER LINE ALL THE WAY TO THE UNIT. 4. FINISH DUCT ON EXHAUST FANS 5. INSTALL OUTSIDE AIR TO UNIT. SPACE HAS NO OPENABLE WINDOWS. RECALL WHEN GRID IS INSTALLED AND DIFFUSERS HOOKED UP |
| 06/20/2000 | ELECTRIC - INTERMEDIATE | N/A | Correction Required | ADDTL COMMS - WALLS FROM COLUMN B TO WEST |
| 06/22/2000 | PLUMBING - INTERMEDIATE | N/A | Correction Required | ADDTL COMMS - 1. NEED A 2 STUB OUT OF WALL A SINK REMOVE 1 1/2 2. SUPPORT H & C WATER LINES 3. QUEST ABS WATER TEST- CUT VENT TO SEE WATER 4. CHECK W.C.O P-7 |
| 08/07/2000 | ELECTRIC - FINAL | N/A | Partial Approval | PLEASE HAVE APPROVED PLANS AVAILABLE AND WILL NEED TO SCREW DOWN FIXTURE TO GRID W/TABS AND SCREWS PROVIDE W/ FIXTURE |
| 08/07/2000 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* REFRIG LINES BE SURE 3/8" COPPER LINE IS COMPLETELY ISOLATED FROM TOUCHING ALL STEEL 2. SUPPLY DUCT WK FINISH WRAPING GALVAN STEEL FITTING OVER STEEL I BEAM GOING TO NEW REST RMS AIR HANDLER DATA PLATE NOT MARKED DOES A/H HAVE AUX HT STRIPS YES WHAT SIZE NO ? DID YOU HAVE IT PROPERLY FUSED EXPOSED CONTROL WIRING AT CONDENSING UNIT NEEDS TO BE IN SEAL TIGHT |
| 08/29/2000 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* |
Completed Inspections
Permit Status: Closed
Permit Number: T99CM05497
Permit Description: ADDITION:OFFICE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2000 | PLUMBING - ROUGH, SOIL | TVALENCI | Approved | ADDTL COMMS - WILL NEED AS BUILTS ON UNDER GROUND WASTE (BEFORE FINAL) |