Permit: T99CM05497

Parcel: 13214013A


Addresses:

727 E EVANS BL

Inspection Status: Correction Required

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
06/15/2000 MECHANICAL - INTERMEDIATE Correction Required ADDTL COMMS - 1. CONDENSATE DRAIN RUNS UPHILL NEED 1/8 PER FOOT MIN SLOPE. 2. CONDENSATE DRAIN CORRECTION TO AIR HANDLER IS CONNECTED TO THE WRONG OUTLET USE THREADED PLUGS IN OUTLETS NOT BEING USED. 3. INSULATE REFER LINE ALL THE WAY TO THE UNIT. 4. FINISH DUCT ON EXHAUST FANS 5. INSTALL OUTSIDE AIR TO UNIT. SPACE HAS NO OPENABLE WINDOWS. RECALL WHEN GRID IS INSTALLED AND DIFFUSERS HOOKED UP
06/15/2000 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection 0000*