Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Final
Type:
DUPLEX NEW
Address:
3075 E ALLEN RD
Address NEW:
3075 E ALLEN RD
Apply Date:
11/18/1999
Applicant:
WALKER DEVELOPMENT
Description:
DUPLEX:TD#12-99-65 (site T99CM04918)
Contractors:
  • WALKER DEVELOPMENT

Completed Inspections

Permit Status: Final
Permit Number: T99CM05486
Permit Description: DUPLEX:TD#12-99-65 (site T99CM04918)
Total Completed Inspections - 13
Date Description Inspector Results Comments
11/19/1999 PLUMBING - ROUGH, SOIL TRINIVJR Approved ADDTL COMMS - 1. SOIL WATER TEST OK 2. SITE SEWER AND HCS CONNECTION OK SITE SEWER OK UP TO NORTH PAD 3. OK TO BACKFILL TRENCH
12/20/1999 FRAMING EMONAHAN Approved IVRS - Inspection 0000$
12/20/1999 FRAMING EMONAHAN Approved ADDTL COMMS - STUD MISSING NORTHSIDE. BLOCK MISSING NORTHSIDE. MISSING RED REBAR SOUTHSIDE.
12/21/1999 PLUMBING - INTERMEDIATE SLONG Approved TESTS OK.NEED PLAN REV.
12/21/1999 PLUMBING - INTERMEDIATE SLONG Approved ADDTL COMMS - DWV OK PLANS ARE CONTRADICTORY REGARDING WATER PIPING, ONE NOTE CALLS FOR TYPE K OR L. ANOTHER NOTE CALLS FOR L,M, OR PB. YOUVE USED TYPE M AND PEX, PLEASE HAVE ARCHITECT CORRECT BY THE NEXT INSPECTION WATER TEST ON PEX OK.
01/04/2000 ELECTRIC - INTERMEDIATE GDEWITT Approved ADDTL COMMS - OK ROUGH NICE JOB
01/26/2000 STUCCO MESH EMONAHAN Approved ADDTL COMMS - 1. NAIL RIB LATHE WALL OFF AT EVERY RIB. 2. NAIL OFF WHERE MISSING AT NORTHWEST CORNER (2 STUDS). 3. NAIL WHERE MISSED AT BOTTOM NORTH CORNER AREA. THEN OKAY.
05/01/2000 ELECTRIC - CABLE DROP RHOLLAND Approved ADDTL COMMS - OK CABLE DROP
05/16/2000 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved ADDTL COMMS - OK TO CLEAR
05/19/2000 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved ADDTL COMMS - 1. WATER SERVICE FROM METER TO BLDG. SERVICE OK 2. OK TO BACKFILL TRENCH
07/07/2000 U VALUE FOR WINDOW EMONAHAN Approved
07/14/2000 PERMIT FINALED DSANTACR Approved
07/26/2000 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW