Permit: T99CM05486

Parcel: 11201014F


Addresses:

3075 E ALLEN RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/26/2000 PLUMBING - INTERMEDIATE Approved
07/08/2000 PLUMBING - INTERMEDIATE Denied 1. WATER CLOSETS MUST HAVE MIN 15" CLEARANCE ON BOTH SIDES
12/21/1999 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - DWV OK PLANS ARE CONTRADICTORY REGARDING WATER PIPING, ONE NOTE CALLS FOR TYPE K OR L. ANOTHER NOTE CALLS FOR L,M, OR PB. YOUVE USED TYPE M AND PEX, PLEASE HAVE ARCHITECT CORRECT BY THE NEXT INSPECTION WATER TEST ON PEX OK.
12/21/1999 PLUMBING - INTERMEDIATE Partial Approval TESTS OK.NEED PLAN REV.
12/20/1999 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. NOT READY FOR INSPECTION.
12/20/1999 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*