Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
5482 S MINORKA PL
Apply Date:
11/12/1999
Applicant:
VARELA DAVID
Description:
AIR COND: & ELECTRICAL PEDISTAL
Contractors:
  • A A ARIZONA MAINTENANCE CO
  • TAPPAN ELECTRIC COMPANY ,

Completed Inspections

Permit Status: Final
Permit Number: T99CM05413
Permit Description: AIR COND: & ELECTRICAL PEDISTAL
Total Completed Inspections - 2
Date Description Inspector Results Comments
11/19/1999 ELECTRIC - CABLE DROP RMAJUTA Approved IVRS - Inspection 0000$
11/19/1999 ELECTRIC - CABLE DROP RMAJUTA Approved ADDTL COMMS - NEED TO CONNECT THE #4 FROM THE GROUND RODS TO THE PEDISTAL NEUTRAL ITS TIED TO THE EQUIPMENT GROUND BUS RUN A JUMPER FROM THE NEUTRAL BUS TO THE EQUIPMENT GROUND BUS AND RECALL