Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
4417 S 16TH AV
Address NEW:
4417 S 16TH AV
Apply Date:
10/18/1999
Applicant:
FLORES JOSE REYES & RAMONA JT/RS
Description:
ADDITION:SHED T99VL01326

Completed Inspections

Permit Status: Final
Permit Number: T99CM04911
Permit Description: ADDITION:SHED T99VL01326
Total Completed Inspections - 6
Date Description Inspector Results Comments
12/13/1999 PERMIT FINALED JRIVA Approved
12/13/1999 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection 0999*
12/13/1999 BUILDING - FINAL JRIVA Approved IVRS - Inspection 0999*
12/13/1999 BUILDING - FINAL JRIVA Approved ADDTL COMMS - RIDGE BEAM MUST BEAR ON POST ON N WALL OR CLIP PER 1/1. INSTALL H2.5 CLIPS ON ALL 2 X 6 RAFTERS. 5 FEET OF INSIDE STORAGE BACK E WALL MUST HAVE 5/8 DRYWALL. STRAP EAST TOPO PLATE TO STUDS BELOW. WIRES MUST EXTEND INTO ELECTRIC BOXES. EXPOSE ELECTRIC UNDERGROUND IN ONE LOCATION. OUTSIDE ELECTRIC OUTLETS MUSTS BE GFIC. INSIDE ELECTRIC OUTLETS MUST BE GFIC OR WALLS FINISHED. ELECTRIC PLAN SHOWS SINGLE 20 AMP CIRCUIT FOR LIGHTS AND ONE OUTLET ACTUALLY 50 AMP INSTALLED. NEED SUB-PANEL AND PLANS REVISED TO AS BUILT
12/13/1999 FRAMING JRIVA Approved IVRS - Inspection 0999*
12/13/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*