Permit: T99CM04911

Parcel: 120022010


Addresses:

4417 S 16TH AV

Inspection Status: Correction Required

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/13/1999 BUILDING - FINAL Correction Required ADDTL COMMS - RIDGE BEAM MUST BEAR ON POST ON N WALL OR CLIP PER 1/1. INSTALL H2.5 CLIPS ON ALL 2 X 6 RAFTERS. 5 FEET OF INSIDE STORAGE BACK E WALL MUST HAVE 5/8 DRYWALL. STRAP EAST TOPO PLATE TO STUDS BELOW. WIRES MUST EXTEND INTO ELECTRIC BOXES. EXPOSE ELECTRIC UNDERGROUND IN ONE LOCATION. OUTSIDE ELECTRIC OUTLETS MUSTS BE GFIC. INSIDE ELECTRIC OUTLETS MUST BE GFIC OR WALLS FINISHED. ELECTRIC PLAN SHOWS SINGLE 20 AMP CIRCUIT FOR LIGHTS AND ONE OUTLET ACTUALLY 50 AMP INSTALLED. NEED SUB-PANEL AND PLANS REVISED TO AS BUILT
12/13/1999 BUILDING - FINAL Denied IVRS - Inspection 0999*