Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
10/14/1999
Applicant:
BECKLIN HOMES
Description:
SFR:TD#14-48-14
Contractors:
  • BECKLIN HOMES

Completed Inspections

Permit Status: Final
Permit Number: T99CM04878
Permit Description: SFR:TD#14-48-14
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/22/1999 EXT METAL CLIPS/EXT SHEATHING BSTEVENS Approved IVRS - Inspection 0999*
12/22/1999 EXT METAL CLIPS/EXT SHEATHING BSTEVENS Approved ADDTL COMMS - 1. PROVIDE ALTERNATE HOLD DOWNS FOR 2 THAT MISSED FRAMING (ALSO NEED C.O.T. AND ENGINEER APPROVAL DOCUMENTATION FOR THIS ALTERNATE) 2. IF LEDGER AT REAR OF HOUSE IS FOR FUTURE PORCH, IT MUST BE ANCHORED WITH APPROPRIATE FRAMING ANCHORS (IE H2.5 OR A35). 3. SHEAR PANELS AT REAR OF HOUSE AND GARAGE FRONT REQUIRE ADDITIONAL NAILING. 4. ADDTIONAL DIAGONAL BRACING NEEDED ON BOTH SIDES OF HOUSE (MAX 25 SPACING)