Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/04/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - ITEMS 1 AND 4 FROM 12/22/99 INSPECTION NOT DONE. |
| 01/04/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |
| 12/22/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - 1. PROVIDE ALTERNATE HOLD DOWNS FOR 2 THAT MISSED FRAMING (ALSO NEED C.O.T. AND ENGINEER APPROVAL DOCUMENTATION FOR THIS ALTERNATE) 2. IF LEDGER AT REAR OF HOUSE IS FOR FUTURE PORCH, IT MUST BE ANCHORED WITH APPROPRIATE FRAMING ANCHORS (IE H2.5 OR A35). 3. SHEAR PANELS AT REAR OF HOUSE AND GARAGE FRONT REQUIRE ADDITIONAL NAILING. 4. ADDTIONAL DIAGONAL BRACING NEEDED ON BOTH SIDES OF HOUSE (MAX 25 SPACING) |
| 12/22/1999 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |