Completed Inspections

Permit Status: Final
Permit Number: T99CM04562
Permit Description: SFR:TD#13-20-72
Total Completed Inspections - 7
Date Description Inspector Results Comments
11/16/1999 ELECTRIC - CABLE DROP RCHAVEZ Approved NO 20 AMP BREAKER
12/23/1999 MECHANICAL - INTERMEDIATE RAIELLO Approved IVRS - Inspection 0999*
12/23/1999 PLUMBING - GAS PRESSURE TEST RAIELLO Approved GAS PRESSURE 25 PSI
12/23/1999 PLUMBING - INTERMEDIATE RAIELLO Approved IVRS - Inspection 0999*
12/23/1999 ELECTRIC - INTERMEDIATE RAIELLO Approved IVRS - Inspection 0999*
12/23/1999 FRAMING RAIELLO Approved IVRS - Inspection 0999*
12/23/1999 FRAMING RAIELLO Approved ADDTL COMMS - 1. PROVIDE STT22S BOTH SIDES OF DOUBLE TOP PLATE AT KITCHEN SHEAR WALL. 2. NAIL GFCI OUTLET AT KITCHEN WALL. 3. KITCHEN EXHAUST HOOD DUCT NOT THROUGH ROOF. 4. PROVIDE SHIMS UNDER HEADERS NOT BEARING ON TRIMMERS AT BEARING WALLS. 5. PROVIDE 1/2 ANCHOR BOLTS AT ENTRY DOOR BOTH SIDES. 6. GROUT TUBS COMPLETELY. 7. LIGHT CAN OVER SINC - IS IT RATED TO BE IN CONTACT WITH ROFFING O.S.B. 8. SUPPORT 4 GANG BOX AT HALL BATH AND MASTER BATH. NOTE: THIS BOX MAY BE OVER LOADED. 9. MOVE ALL AQUA PEX MIN. 12 FROM ALL LIGHT CANS. 10.SECURE TUB DIVERTERS. 11.NAIL OFF FHA AT LAUNDRY DRYER DUCT. STOPPED INSPECTION.