Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
9793 E PASEO JUAN TABO
Apply Date:
08/26/1999
Applicant:
U S HOME OF ARIZONA
Description:
SFR:TD#13-97-03
Contractors:
  • U S HOME OF ARIZONA

Completed Inspections

Permit Status: Final
Permit Number: T99CM04130
Permit Description: SFR:TD#13-97-03
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/01/1999 ROOF NAILING MCAPISTR Approved ADDTL COMMS - 0. SHEARWALLS REQUIRE DBL. 2X STUD AT EA. END. SEE TYPICAL SHEARWALL DETAIL. 1. ANCHOR BOLTS-SEVERAL MISSING- MUST BE WITHIN 12 OF EACH END. 2. ANCHOR BOLTS-OVERSIZE HOLE BORED IN BOTTOM PLATE. USE LARGER WASHER WHERE OVERSIZE HOLE ALLOWS WASHER (INSTALLED) TO SINK IN. 4. WIND STRAPS MUST HAVE TWO (2) NAILS AT EACH END AND AT EVERY STUD. 5. COIL STRAPS INSTALLED FOR FLOOR TO FLOOR CONNECTION ARE UNDER NAILED AT SOME LOCATIONS. 6. FIREBLOCK SOFFITT AT OUTSIDE WALL (KITCHEN). 7. CHIMNEY PLAT FORM FRAMING-STRAP EACH CORNER FROM PLAT FORM TO PLAT FORM-2 SECTIONS. 8. BEAM AT FRONT OF GARAGE NOT CAPPED WITH APPROVED SIMPSON POST CAPS 9
12/23/1999 FRAMING MCAPISTR Approved IVRS - Inspection 0000*
12/23/1999 FRAMING MCAPISTR Approved ADDTL COMMS - THE FRAMING IS PARTIALLY APPROVED PENDING PRESENTATION OF A REVISION APPROVED ABY THE ENGINEER OF RECORD AND CITY OF TUCSON PLANS EXAMINER FOR THE FOLLOWING ITEMS: THE SUBSTITUTION OF THE SPECIFIED SIMPSON POST CAPS AND POST BASES FOR THE ATTACHMENT OF THE BEAM SPANNING ACROSS THE FRONT OF THE GARAGE.