Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
1302 S CAMINO ARRIBA
Apply Date:
06/14/1999
Applicant:
GONZALES LEONARD
Description:
ADDITION:2 BEDROOMS/DINING & LNDRY ROOM

Permit Reviews

Permit Number - T99CM02855
Permit Status: Expired
Permit Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Start Date Submittal Complete Date Status  
02/21/2001 REVISION 11/27/2001 STOPPED Review Details
09/12/2000 REVISION 02/08/2001 STOPPED Review Details
11/29/2002 REVISION 12/02/2002 COMPLETED Review Details

Outstanding Inspections

Permit Status: Expired
Permit Number: T99CM02855
Permite Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
U VALUE FOR WINDOW N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
01/02/2003 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY
04/24/2002 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*/ 1) ELECTRIC INTERMEDIATE APPROVED PREVIOUSLY 2) DRYER VENT OK HALL AC REGISTER BLOCKED ON 3 SIDES 3) MECHANICAL INTERMEDIATE APPROVED 4) OK TO PROCEED W/INSULATION AND DRYWALL FIREPLACE UNIT IS ELECTRIC NO FLUE REQUIRED
07/25/2000 FRAMING N/A Partial Approval IVRS - Inspection 0000*/FRAMING WILL BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETE AND APPROVED. 1. 4 X 6 LEDGER AND RAFTERS NOT INSTALLED PER PLAN MISSING LAG 1/2 X 8" REVISE PLAN AND SUBMIT FOR APPROVAL. 2. PROVIDE VERTICAL DEFLECTION 1/2 PROVIDE TRUSS BRACING 10' O.C. RAT RUN. 3. BLOCK BETWEEN TRUSSES (STANDARD). 4. SITE PLAN DOESN'T MATCH AS BUILT SHOULD BE 11' SEPERATION FROM ADDITION TO CARPORT ADDITION.

Completed Inspections

Permit Status: Expired
Permit Number: T99CM02855
Permit Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/13/2000 MECHANICAL - INTERMEDIATE RAIELLO Approved IVRS - Inspection 0999*
09/13/2000 ELECTRIC - INTERMEDIATE RAIELLO Approved IVRS - Inspection 0999*/1. EXHAUST VENT NOT COMPLETE AT LAUNDRY. 2. MECHANICAL NOT BLOCKED 3 SIDES. 3. FIRE PLACE NOT INSTALLED. 4. ELECTRIC NOT COMPLETE TO ROOF A/C. 5. MECHANICAL NOT COMPLETE TO ROOF A/C/ GAS PACK. 6. GABLE END TRUSS DESTROYED AT AC/GAS PACK FOR DUCT PENETRATION PROVIDE APPROVED REPAIR. 7. NO APPROVED PLANS OR PERMITS ON SITE.
06/28/2002 STUCCO MESH DBRITO Approved IVRS - Inspection 0000*
01/02/2003 SHEET ROCK NAILING EDURAZO Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW