Permit: T99CM02855
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
1302 S CAMINO ARRIBA
Address NEW:
1302 S CAMINO ARRIBA
Apply Date:
06/14/1999
Applicant:
GONZALES LEONARD
Description:
ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Permit Reviews
Permit Number - T99CM02855
Permit Status: Expired
Permit Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/21/2001 | REVISION | 11/27/2001 | STOPPED |
| 09/12/2000 | REVISION | 02/08/2001 | STOPPED |
| 11/29/2002 | REVISION | 12/02/2002 | COMPLETED |
Outstanding Inspections
Permit Status: Expired
Permit Number: T99CM02855
Permite Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| U VALUE FOR WINDOW | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| 01/02/2003 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NOT READY |
| 04/24/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) ELECTRIC INTERMEDIATE APPROVED PREVIOUSLY 2) DRYER VENT OK HALL AC REGISTER BLOCKED ON 3 SIDES 3) MECHANICAL INTERMEDIATE APPROVED 4) OK TO PROCEED W/INSULATION AND DRYWALL FIREPLACE UNIT IS ELECTRIC NO FLUE REQUIRED |
| 07/25/2000 | FRAMING | N/A | Partial Approval | IVRS - Inspection 0000*/FRAMING WILL BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETE AND APPROVED. 1. 4 X 6 LEDGER AND RAFTERS NOT INSTALLED PER PLAN MISSING LAG 1/2 X 8" REVISE PLAN AND SUBMIT FOR APPROVAL. 2. PROVIDE VERTICAL DEFLECTION 1/2 PROVIDE TRUSS BRACING 10' O.C. RAT RUN. 3. BLOCK BETWEEN TRUSSES (STANDARD). 4. SITE PLAN DOESN'T MATCH AS BUILT SHOULD BE 11' SEPERATION FROM ADDITION TO CARPORT ADDITION. |
Completed Inspections
Permit Status: Expired
Permit Number: T99CM02855
Permit Description: ADDITION:2 BEDROOMS/DINING & LNDRY ROOM
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2000 | MECHANICAL - INTERMEDIATE | RAIELLO | Approved | IVRS - Inspection 0999* |
| 09/13/2000 | ELECTRIC - INTERMEDIATE | RAIELLO | Approved | IVRS - Inspection 0999*/1. EXHAUST VENT NOT COMPLETE AT LAUNDRY. 2. MECHANICAL NOT BLOCKED 3 SIDES. 3. FIRE PLACE NOT INSTALLED. 4. ELECTRIC NOT COMPLETE TO ROOF A/C. 5. MECHANICAL NOT COMPLETE TO ROOF A/C/ GAS PACK. 6. GABLE END TRUSS DESTROYED AT AC/GAS PACK FOR DUCT PENETRATION PROVIDE APPROVED REPAIR. 7. NO APPROVED PLANS OR PERMITS ON SITE. |
| 06/28/2002 | STUCCO MESH | DBRITO | Approved | IVRS - Inspection 0000* |
| 01/02/2003 | SHEET ROCK NAILING | EDURAZO | Approved | IVRS - Inspection 0000* |