Permit: T99CM02855

Parcel: 118050500

Inspection Status: Denied

Inspection History: FRAMING

Date Description Inspector Results Comments
03/27/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ELECTRIC WIRE AT NORHT JUST HANGING 2) FIREPLACE NOT COMPLETE 3) BLOCKS AT MECHANICAL REGISTER IN HALL 4) SMOKE DETECTORS REQUIRE 36" DISTANCE FROM MECHANICAL OUTLETS
02/01/2002 FRAMING Denied IVRS - Inspection 0999*
07/25/2000 FRAMING Partial Approval IVRS - Inspection 0000*/FRAMING WILL BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETE AND APPROVED. 1. 4 X 6 LEDGER AND RAFTERS NOT INSTALLED PER PLAN MISSING LAG 1/2 X 8" REVISE PLAN AND SUBMIT FOR APPROVAL. 2. PROVIDE VERTICAL DEFLECTION 1/2 PROVIDE TRUSS BRACING 10' O.C. RAT RUN. 3. BLOCK BETWEEN TRUSSES (STANDARD). 4. SITE PLAN DOESN'T MATCH AS BUILT SHOULD BE 11' SEPERATION FROM ADDITION TO CARPORT ADDITION.