Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
950 W TETON ST
Address NEW:
950 W TETON ST
Apply Date:
06/08/1999
Applicant:
ROMERO FRANK M & MARIA C
Description:
SFR

Completed Inspections

Permit Status: Final
Permit Number: T99CM02763
Permit Description: SFR
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/08/1999 ROOF NAILING JRIVA Approved IVRS - Inspection 0999*
12/08/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*
12/08/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved ADDTL COMMS - OSB SHEAR PANELS MUST BE NAILED AT TOP AND BOTTOM PLATES AND ALL SUPPORTED EDGES AND BLOCK MID SPAN AS REQUIRED. GIRDER TRUSS IN GARAGE MUST BEAR ON TRIPPLE 2 X 6S BELOW. HIP TRUSSES AT ENTRY MUST BEAR ON HANGER. TRUSSES MUST BEAR ON INTERIOR BEARING WALLS. NO TRUSS DRAWINGS-CITY OF TUCSON TRUSS ENGINEERING DRAWINGS MUST BE ON SITE. 2 X 12 BEAMS AT ENTRY NOT CLIPPED TO STRUCTURE. ALSO TRUSSES NOT CLIPPED. REAR PORCH 6 X 6 POSTS & BEAMS REQUIRE POST CAP CONNECTORS. GABLE TRUSSES MUST BE CLIPPED TO WALLS AT 32 O.C. SHEAR WALL 4 REQUIRES NAILING AT 3 O.C. 2/5 NOT COMPLIED WITH. ROOF NOT INSPECTED

Documents

File Name Document Type  
T99CM02763 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW