Permit: T99CM02763

Parcel: 13822013P


Addresses:

950 W TETON ST

Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/12/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 5. CRIPPLE STUDS AND H2.5. CLIPS REQUIRED AT E. 4040 WINDOWS STUDS AT 16 O.C. AND 3020 WINDOW. 9. ALL INTERIOR BEARING WALLS MUST BE CLIPPED TOP AND BOTTOM PLATES AND TOP PLATES TO TRUSSES.
01/12/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
01/03/2000 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - 13. CLIP ALL HEADERS.
01/03/2000 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*
12/08/1999 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - OSB SHEAR PANELS MUST BE NAILED AT TOP AND BOTTOM PLATES AND ALL SUPPORTED EDGES AND BLOCK MID SPAN AS REQUIRED. GIRDER TRUSS IN GARAGE MUST BEAR ON TRIPPLE 2 X 6S BELOW. HIP TRUSSES AT ENTRY MUST BEAR ON HANGER. TRUSSES MUST BEAR ON INTERIOR BEARING WALLS. NO TRUSS DRAWINGS-CITY OF TUCSON TRUSS ENGINEERING DRAWINGS MUST BE ON SITE. 2 X 12 BEAMS AT ENTRY NOT CLIPPED TO STRUCTURE. ALSO TRUSSES NOT CLIPPED. REAR PORCH 6 X 6 POSTS & BEAMS REQUIRE POST CAP CONNECTORS. GABLE TRUSSES MUST BE CLIPPED TO WALLS AT 32 O.C. SHEAR WALL 4 REQUIRES NAILING AT 3 O.C. 2/5 NOT COMPLIED WITH. ROOF NOT INSPECTED
12/08/1999 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*