Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
2102 S MONTEZUMA AV
Apply Date:
06/01/1999
Applicant:
HAMILTON WANDA J
Description:
UPGRADE:ELECTRIC TO 200 AMP & ROOFTOP UNIT

Completed Inspections

Permit Status: Final
Permit Number: T99CM02609
Permit Description: UPGRADE:ELECTRIC TO 200 AMP & ROOFTOP UNIT
Total Completed Inspections - 8
Date Description Inspector Results Comments
12/03/1999 ELECTRIC - CABLE DROP RSUBA Approved DENIED
12/03/1999 ELECTRIC - CABLE DROP RSUBA Approved ADDTL COMMS - INSTALL #4 GROUNDING ELECTRODE CONDUCTOR. 1. CODE REQUIRES 2 GROUND RODS MIN. 6 APART AND #4 WATER BOND. 2. SECURE CONDUIT ON ROOK. 3. ALL ROMEX BELOW ROOK SHALL BE REQUIRED TO BE INSTALLED IN AN APPROVED CONDUIT SYSTEM.
12/06/1999 PLUMBING - GAS PRESSURE TEST SLONG Approved 10#TEST REQD, SEC.LINE
12/06/1999 PLUMBING - GAS PRESSURE TEST SLONG Approved ADDTL COMMS - GAS TEST REQUIRES 10# FOR 15 MINUTES SECURE GAS LINE CHPT 12.UPC
12/06/1999 ELECTRIC - SERVICE UPGRADE RSUBA Approved DENIED
12/06/1999 ELECTRIC - SERVICE UPGRADE RSUBA Approved ADDTL COMMS - 1. INSTALL GROUNDING ELECTRODE SYSTEM 2 RIDS AT KEAST 6 APART (USE #4A.W.G. COPPER ) 2. INSTALL #4 WATER BOND TO WATER PIPING AND CONNECT TO NEUTRAL GROUNDING BUS BAR
03/27/2000 PERMIT FINALED RSUBA Approved
11/14/2000 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*