Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
816 N CONTZEN AV
Address NEW:
816 N CONTZEN AV
Apply Date:
05/06/1999
Applicant:
N/A
Description:
SFR:TD#13-74-69
Contractors:
  • LA CAUSA CONSTRUCTION INC

Completed Inspections

Permit Status: Final
Permit Number: T99CM02167
Permit Description: SFR:TD#13-74-69
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/22/1999 ROOF NAILING JRIVA Approved DENIED
12/22/1999 ROOF NAILING JRIVA Approved ADDTL COMMS - 1. CARPORT NOT PER 12/10. 2. CARPORT REQUIRES ST 2115 STRAPS. 3. NO CITY APPROVED TRUSS DRAWINGS ON SITE. 4. INCORRECT HOLD DOWNS INSTALLED - HPAHD22S REQUIRED PAHD 42S INSTALLED. 5. HOLD DOWN MISSING AT STORAGE CORNER OF CARPORT PROVIDE CITY APPROVED ENGINEERING FOR ALL HOLD DOWN REPAIRS. 6. 15/10 NOT COMPLIED WITH. 7. 2/10 REQUIRED AT 48 O.C. 8. CLIP EVERY STUD ON BEARING WALLS TOP AND BOTTOM. 9. SHEAR WALLS 2 REQUIRE MID SPAN BLOCKING. 10. MANY O.S.B. ROOF PANELS NOT PROPERLY NAILED.
12/22/1999 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW