Inspection Status: Denied
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/26/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999* |
| 12/22/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. CARPORT NOT PER 12/10. 2. CARPORT REQUIRES ST 2115 STRAPS. 3. NO CITY APPROVED TRUSS DRAWINGS ON SITE. 4. INCORRECT HOLD DOWNS INSTALLED - HPAHD22S REQUIRED PAHD 42S INSTALLED. 5. HOLD DOWN MISSING AT STORAGE CORNER OF CARPORT PROVIDE CITY APPROVED ENGINEERING FOR ALL HOLD DOWN REPAIRS. 6. 15/10 NOT COMPLIED WITH. 7. 2/10 REQUIRED AT 48 O.C. 8. CLIP EVERY STUD ON BEARING WALLS TOP AND BOTTOM. 9. SHEAR WALLS 2 REQUIRE MID SPAN BLOCKING. 10. MANY O.S.B. ROOF PANELS NOT PROPERLY NAILED. |
| 12/22/1999 |
ROOF NAILING |
|
Denied |
DENIED |