Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
03/29/1999
Applicant:
KAUFMAN AND BROAD OF ARIZONA INC
Description:
SFR:TD#14-14-62
Contractors:
  • KAUFMAN AND BROAD

Completed Inspections

Permit Status: Final
Permit Number: T99CM01407
Permit Description: SFR:TD#14-14-62
Total Completed Inspections - 4
Date Description Inspector Results Comments
04/16/1999 BUILDING PRE-SLAB RAIELLO Approved ADDTL COMMS - 1. PLANS CALL FOR SIMPSON PAHD42 THESE REQUIRE 2-6 OF #4 UNDER EACH STRAP. THE CONTRACTOR WANTS TO INSTALL HPAHD 22 THAT DO NOT REQUIRE #4 IN A POST TENSION SLAB PER SIMPSON. PLANS SHOULD BE CHANGED TO REFLEX THIS.
04/30/1999 ROOF NAILING MCAPISTR Approved ADDTL COMMS - 2. SUBMIT A REVISED DRAWING JUSTIFYING CHANGE IN GABLE/GIRDER TRUSS D AT GARAGE. PLAN SHEET 8 REQUIRES THIS TRUSS HAVE A 2X6 BOTTOM CHORD (MINIMUM). OR, SUBMIT A TRUSS MFRRS REMEDY.
04/30/1999 EXT METAL CLIPS/EXT SHEATHING MCAPISTR Approved ADDTL COMMS - 1. PER PREVIOUS INSPECTORS NOTE, SUBMIT A REVISED DRAWING WITH APPROVALS FOR THE WIDER WINDOW AT LIVING ROOM. JUSTIFY HEADER SIZE AND REDUCED SHEAR WALL 3.
05/07/1999 FRAMING MCAPISTR Approved ADDTL COMMS - CORRECTIONS REQUESTED BY M. SNYDER COMPLETED.

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW