Permit: T99CM01407
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
1779 W RUE DE LA MONTAGNE
Address NEW:
1779 W RUE DE LA MONTAGNE
Apply Date:
03/29/1999
Applicant:
KAUFMAN AND BROAD OF ARIZONA INC
Description:
SFR:TD#14-14-62
Contractors:
- KAUFMAN AND BROAD
Completed Inspections
Permit Status: Final
Permit Number: T99CM01407
Permit Description: SFR:TD#14-14-62
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/1999 | BUILDING PRE-SLAB | RAIELLO | Approved | ADDTL COMMS - 1. PLANS CALL FOR SIMPSON PAHD42 THESE REQUIRE 2-6 OF #4 UNDER EACH STRAP. THE CONTRACTOR WANTS TO INSTALL HPAHD 22 THAT DO NOT REQUIRE #4 IN A POST TENSION SLAB PER SIMPSON. PLANS SHOULD BE CHANGED TO REFLEX THIS. |
| 04/30/1999 | ROOF NAILING | MCAPISTR | Approved | ADDTL COMMS - 2. SUBMIT A REVISED DRAWING JUSTIFYING CHANGE IN GABLE/GIRDER TRUSS D AT GARAGE. PLAN SHEET 8 REQUIRES THIS TRUSS HAVE A 2X6 BOTTOM CHORD (MINIMUM). OR, SUBMIT A TRUSS MFRRS REMEDY. |
| 04/30/1999 | EXT METAL CLIPS/EXT SHEATHING | MCAPISTR | Approved | ADDTL COMMS - 1. PER PREVIOUS INSPECTORS NOTE, SUBMIT A REVISED DRAWING WITH APPROVALS FOR THE WIDER WINDOW AT LIVING ROOM. JUSTIFY HEADER SIZE AND REDUCED SHEAR WALL 3. |
| 05/07/1999 | FRAMING | MCAPISTR | Approved | ADDTL COMMS - CORRECTIONS REQUESTED BY M. SNYDER COMPLETED. |