Description:
POOL:GUNITE TD#13-94-81
Contractors:
  • PATIO POOLS & SPAS

Completed Inspections

Permit Status: Final
Permit Number: T99BU00309
Permit Description: POOL:GUNITE TD#13-94-81
Total Completed Inspections - 1
Date Description Inspector Results Comments
03/04/1999 POOL/SPA PRE-GUNITE MSNYDER Approved ADDTL COMMS - 1. BOND BEAM TO 1 1/2 FROM FORM. 2. SPA LIGHT SEAMS TO EXTEND IN TO LEG SPACE AS PER PLAN. 3. BOND WIRES MAY BE NEEDED FOR WROUGHT IRON FENCE. 4. MIN 20 SPLICES ( NOT SO IN A FEW AREAS) 5. GFCI TO BE MIN OF 10 FROM POOL EDGE. ALL ITEMS 1-5 HAVE BEEN COMPLETED.