Date Description Inspector Results Comments
12/31/1998 ROOF NAILING JRIVA Approved IVRS - Inspection 0000*
12/31/1998 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*
12/31/1998 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved ADDTL COMMS - 1. CLIP FRONT GABLE TO WALL AT 32 O.C. 2. OVER SPAN ON FRONT SHEAR STUD MISSING. 3. CLIP GARAGE HEADER TO KING STUDS. 4. OVER SPAN GARAGE WALL BEARIGN STUDS MUST BE SPACED NOT MORE THAN 16 O.C. 2 PLACES. 5. PROVIDE FOR DRYWALL SHEAR TRANSFER AT INTERSECTING WALL CHANELS. 6. SHIM 3 POINT TRUSS AT BEARING POINT. 7. TRUSS PLAN AND BRACES NOT IN.