Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T98CM05073
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/06/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. HOUSE DOES NOT MATCH TRUSS PLAN AT MID BEARING POINT. | |
12/31/1998 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. CLIP FRONT GABLE TO WALL AT 32 O.C. 2. OVER SPAN ON FRONT SHEAR STUD MISSING. 3. CLIP GARAGE HEADER TO KING STUDS. 4. OVER SPAN GARAGE WALL BEARIGN STUDS MUST BE SPACED NOT MORE THAN 16 O.C. 2 PLACES. 5. PROVIDE FOR DRYWALL SHEAR TRANSFER AT INTERSECTING WALL CHANELS. 6. SHIM 3 POINT TRUSS AT BEARING POINT. 7. TRUSS PLAN AND BRACES NOT IN. | |
12/31/1998 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |