Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
3240 N CHRISTMAS AV
Apply Date:
11/17/1998
Applicant:
TORTOLITA ENTERPRISES INC ,
Description:
ADDITION:FAMILY ROOM
Contractors:
  • TORTOLITA ENTERPRISES INC ,

Outstanding Inspections

Permit Status: Expired
Permit Number: T98CM05036
Permite Description: ADDITION:FAMILY ROOM
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
PLUMBING - SEWER HCS CONNECT N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
PERMIT FINALED N/A Not Inspected
12/09/1999 PLUMBING - ROUGH, SOIL N/A Correction Required ADDTL COMMS - SHOWER VENT CONNECTION IS WET VENT. NOT ALLOWED VENT WYE MUST CONNECT TO DRAIN ABOVE THE CENTER LINE OF THE DRAIN.

Completed Inspections

Permit Status: Expired
Permit Number: T98CM05036
Permit Description: ADDITION:FAMILY ROOM
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/22/1999 ROOF NAILING ROHAVER Approved IVRS - Inspection 0999*
09/22/1999 ROOF NAILING ROHAVER Approved ADDTL COMMS - 1. RAFTERS NOTCHED MORE THAN 25%. 2. HEAD ST 22 STRAPS PEAK ACROSS. RIDGE BOARD ATTACHED TO RAFTERS. 3. ROOF PITCH LESS THAN 3/12 TO HAVE REQUIRED BEAM OR COLLAR TIES INSTALLED. 4. EXCAVATE POST FOOTINGS, CALL FOR INSPECTION. 5. POUR AFTER APPROVAL. ATTACH POSITIVE CORRECTIONS,BOTH ENDS PORCH PORTS. 6. INSTALL H25S PORCH RAFTER TO BEAM.
10/20/1999 EXCAVATION/LAYOUT REBAR & ZON RCHAVEZ Approved ADDTL COMMS - PORCH FOOTINGS OK.
01/26/2000 ELECTRIC - INTERMEDIATE JRIVA Approved ADDTL COMMS - CLEAN SERVICE INCREASE AND RELOCATION.