Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Address NEW:
1706 E HEDRICK DR #02
Apply Date:
10/02/1998
Applicant:
NATASHA WINNIK
Description:
SFR:STRAW BALE

Outstanding Inspections

Permit Status: Expired
Permit Number: T98CM04266
Permite Description: SFR:STRAW BALE
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected
06/23/2000 BUILDING - FINAL N/A Not ready for Inspection 1. SERVICE PANEL NOT PROPERLY GROUNDED. CONNECT UFER BY CONDUCTOR TO LARGE LUG OF NEUTRAL BAR. 2. RISER BONDING RING MUST BE CONNECTED TO PANEL NEUTRAL.
06/23/2000 ELECTRIC - FINAL N/A Not ready for Inspection
06/23/2000 PLUMBING - FINAL N/A Not ready for Inspection
06/23/2000 MECHANICAL - FINAL N/A Not ready for Inspection