Permit: T98CM02020
Permit Details
Apply Date:
05/08/1998
Applicant:
U S HOME OF ARIZONA CONSTRUCTION
Description:
SFR:TD#13-14-76
Contractors:
- U S HOME OF ARIZONA CONSTRUCTION
Completed Inspections
Permit Status: Final
Permit Number: T98CM02020
Permit Description: SFR:TD#13-14-76
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/1998 | EXT METAL CLIPS/EXT SHEATHING | MCAPISTR | Approved | ADDTL COMMS - THE UBC REQUIRES THAT WHERE THE FLOOR PLATE/ BOTTOM PLATES HAS BEEN CUT AWAY TO ALLOW PIPING THROUGH, FHA STRAPS MUST BE INSTALLED ON BOTH SIDES OF THE PLATE TO REINFORCE IT. THE STRAPS MUST BE FASTENED IN PLACE WITH A MINIMUM THREE (3) 8D NAILS AT EACH END. INSTALL THESE STRAPS BEFORE APPLYING EXTERIOR LATH. THE CODE DOES NTO ALLOW ANY OTHER METHOD TO SUBSTITUTE FOR FHA STRAPS. INSTALL THE MISSING ANCHOR BOLTS MARKED X ON BOTTOM PLATE. |