Permit: T98CM02020

Parcel: 136089070


Addresses:

2471 S CYBIL AV


Inspection Status: Correction Required

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T98CM02020

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Correction Required

Date Description Inspector Results Comments
05/19/1998 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDTL COMMS - THE UBC REQUIRES THAT WHERE THE FLOOR PLATE/ BOTTOM PLATES HAS BEEN CUT AWAY TO ALLOW PIPING THROUGH, FHA STRAPS MUST BE INSTALLED ON BOTH SIDES OF THE PLATE TO REINFORCE IT. THE STRAPS MUST BE FASTENED IN PLACE WITH A MINIMUM THREE (3) 8D NAILS AT EACH END. INSTALL THESE STRAPS BEFORE APPLYING EXTERIOR LATH. THE CODE DOES NTO ALLOW ANY OTHER METHOD TO SUBSTITUTE FOR FHA STRAPS. INSTALL THE MISSING ANCHOR BOLTS MARKED X ON BOTTOM PLATE.