Permit: T98CM01324
Permit Details
Apply Date:
03/31/1998
Applicant:
FLORES LUIS
Description:
ADDITION:EXERCISE ROOM
Contractors:
- R C G CONSTRUCTION INC ,
Completed Inspections
Permit Status: Final
Permit Number: T98CM01324
Permit Description: ADDITION:EXERCISE ROOM
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/28/1998 | ROOF NAILING | RFREIDIN | Approved | ADDTL COMMS - 1. VERIFY THAT H2O LINES ARE NOT OVER LOADING SYSTEM AFTER COMING OFF A 3/4 H2O LINE YOU CAN HAVE 3 FIXTURES ON THAT 1/2 LINE NO MORE. 2. USE COPPER OR BRASS PLUG AT SHOWER NO THREADED JOINTS TO BE CONCELED. 3. MAKE UP ALL ELECT BOXES, GRDS, NEUTRALS. 4. PER PLAN YOU NEED A BATHROOM EXHAUST FAN. 5. YOU NEED 2 METAL AT PLATE LINE SEE YOU STUCCO INSTALLATION SHEET FOR DETAILS. 6. ADD BLOCKS AT EXISTING WALL AND SECURE NEW WALL. 7. CIRCUIT FOR BATHROOM OUTLET TO BE BY ITSELF NO OTHER OUTLETS ALLOWED. 8. 14 GAUGE WIRE OLD SPRINKLER CIRCUIT TO BE REMOVED. |