Permit: T98CM01077
Permit Details
Apply Date:
03/12/1998
Applicant:
HANCOCK BRENT & CRISTINE JT/RS
Description:
ADDITION:BEDROOM &BATHROOM & STUDY
Completed Inspections
Permit Status: Final
Permit Number: T98CM01077
Permit Description: ADDITION:BEDROOM &BATHROOM & STUDY
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/1998 | STEM WALL/RETAINING WALL | RFREIDIN | Approved | ADDTL COMMS - 1. 4 BLOCK NOT A GOOD BLDG. PRACTICE NOT ANY ROOM FOR GROUT NOT MUCH STRENGTH TO HOLD TO 2 STEM. 2. YOU NEED 7 EMBEDDMENT FOR AB. 3. PLEASE CALL FOR PRE SLAB INSP. |
| 07/24/1998 | BUILDING PRE-SLAB | RFREIDIN | Approved | ADDTL COMMS - 1. NOT ENOUGH BEARING SURFACE WITH 12X12 POST PAD CHANGE TO POST BASE FTG WAS CORRECTED TO READ 18 WIDE X18. |
| 07/31/1998 | ELECTRIC - SERVICE RELOCATION | RFREIDIN | Approved | NOT READY FOR INSPECTION |
| 07/31/1998 | ELECTRIC - SERVICE RELOCATION | RFREIDIN | Approved | ADDTL COMMS - 1. NEW ELEC SERV REQUIRES TWO GRD RODS. |
| 08/03/1998 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | ADDTL COMMS - 1. I LEFT A CHART FOR SIZING GAS LINES. 2. TO MAKE SURE 3/4 IS SUFFICENT I CAN SIZE YOUR GAS LINE BUT NEED A DIAGRAM WITH MEASURMENTS SEE BACK OF CHART. |
| 10/07/1998 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | ADDTL COMMS - 1. MAKE UP ALL ELECT BOXES BOND SCREW ALL METAL. 2. FINISH MECHANICAL DUCT. 3. CHECK ALL WIRES FOR SHEET ROCK NAIL PROTECTION. |