Permit: T98CM00118
Permit Details
Apply Date:
01/12/1998
Applicant:
HERNANDEZ JOSE G & ARLENE R JT/R
Description:
ADDITION:KITCHEN & ENCLOSE:CARPORT FOR FAMILY
Completed Inspections
Permit Status: Final
Permit Number: T98CM00118
Permit Description: ADDITION:KITCHEN & ENCLOSE:CARPORT FOR FAMILY
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/01/1999 | PLUMBING - FINAL | MCAPISTR | Approved | IVRS - Inspection 0999* |
09/01/1999 | PLUMBING - FINAL | MCAPISTR | Approved | ADDTL COMMS - 1. THE DISHWASHER AND DISPOSAL PLUG CANNOT BE ON THE KITCHEN CIRCUIT. RECEPTACLES W/G F1 PROTECTION MUST BE ADDED TO ISLAND AND PENNINSULA COUNTERS. |
09/01/1999 | BUILDING - FINAL | MCAPISTR | Approved | IVRS - Inspection 0999* |
09/01/1999 | BUILDING - FINAL | MCAPISTR | Approved | ADDTL COMMS - 1. THE KITCHEN COUNTER PLUGS ARE SUPPOSED TO BE ON TWO CIRCUITS WHICH SERVE THOSE PLUGS ONLY. 2. THE DISHWASHER AND DISPOSER PLUG CANNOT BE ON THE KITCHEN CIRCUIT. CORRECT AND RECALL. 3. THE KITCHEN LIGHTING CANNOT BE ON THE COUNTER PLUG CIRCUIT. RECEPTACLES W/G F1 PROTECTION MUST BE ADDED TO ISLAND AND PENNINSULA COUNTERS. |